Safety instructions for handling UV radiation products
UV radiation is highly effective and requires simple and uncomplicated measures for personal
protection. As simple and straightforward as these are, it is important to adhere to them. We will be
happy to explain to you in detail whether and which measures are required for your application or
setup.
Feel free to contact us if you have any questions.
description
Information
UV radiation
UV (UV-A,UV-B,UV-C) radiation is dangerous for the eyes and skin. UV radiation
sources may therefore only be operated with appropriate personal protection
measures. This does not apply if the device is closed and from which no UV radiation
can escape (air disinfection systems based on circulating air, etc.).
Protection from
UV radiation at approx. 254 nm (UV-C) can be shielded by normal window glass
UV
(borosilicate, Duran, etc.), transparent plastics such as Makrolon®, Plexiglas® and
practically all opaque materials. Further information on UV filters can be found in the
"EN 170 - Personal eye protection" standard. Quartz glass is permeable to UV-C
radiation and must never be used as protective glass for personal protection.
Installation and
Changeover circuits, information signs or forced shutdowns are to be attached at the
operation
responsibility and at the discretion of the operator. If individual components are put
into operation for integration in systems and devices or sample deliveries, it is the
operator's responsibility to observe the relevant electrotechnical regulations. The
components should only be commissioned by trained, trained personnel.
Material
Objects can discolour after long and intensive UV exposure. We recommend using UV-
resistance
resistant materials. When using ozone-forming radiation sources, it should be noted
that ozone has a strong oxidative effect.
Ozone
When using ozone-forming UV radiation sources, the MAK value (MAK = maximum
formation
workplace concentration) of 0.1 ppm must be observed. It is advisable to use a
suitable area with an air vent for experimental setups.
Temperature
Low-pressure lamps have a light tube temperature of approx. 40 ° C during operation.
These have to cool down sufficiently before being touched. It is not necessary to cool
down simple low-pressure emitters for re-ignition.
Accessory
Item-no.
UVC20WT6L
Schmelter LED-Technology GmbH
Bestwig
UVCARE-midi Standfuß
HRB 9330
AG: Arnsberg
Steuer Nr.: 334/5733/2256
Umsatzsteuer ID Nr.: DE273464160
EORI-Nr. DE1113054
WEEE Reg.Nr.: DE58361175
Description
UV-C tube 20 W
Bankverbindung:
Stainless steel feet for UV-Care midi
Commerzbank AG
(Set with 2 pieces)
BIC/Swift: COBADEFFXXX
IBAN: DE0345840026 0280 014200
Fax:
+49 (2904) – 711 60-29
E-Mail:
info@led-schmelter.de
Web:
www.led-schmelter.de
Image
Sparkasse Hochsauerland
Swift/BIC: WELADED1HSL
IBAN: DE6841651770 0000 071316
Geschäftsführer:
Joachim Schmelter
AGB auch unter:
www.led-schmelter.de
Präqualifiziert nach PQ-VOL