been exceeded.
Never insert objects of any kind into the intake or exhaust
fins as this can damage the fan. The device is self-cleaning
inside. Since there are no filter mats, there is no need to
change the filter material. If necessary, clean the outside
with a damp cloth and make sure that no liquid gets inside
the UVCARE®.
If these safety instructions are observed, operation, even
in 24h mode, is harmless.
The product is to be installed inaccessible to children.
In the event of any visible defects, the device must be shut
down immediately and returned to the manufacturing
plant for inspection.
5. How long can UVCARE® be operated?
There are no restrictions in operation. 24h operation is
permitted. Since an optimal disinfection result is only
achieved after the room air has been circulated approx. 4-
8 times, appropriate lead times should be taken into
account.
After a running time of min. 9000h the UVC lamp must be
exchanged to/for a similar one.
First, the UVCARE® must be completely disconnected from
the power supply and opened by unscrewing the locking
screw and the suction cover. The tube can be removed by
turning it through 90 ° (rotary plug socket) and the
replacement tube can be inserted in the same way. Then
secure the cover by twisting it and screw in the locking
screw. Only then reconnect the power supply.
The tube contains Hg and must be disposed of in
accordance with local regulations that also apply to
fluorescent tubes.
6. Are there any side effects when using the UVCARE®?
UVCARE® destroys the ability of microorganisms, viruses
and bacteria to multiply. This allows ozone to be released
in a purely physical process. However, the concentration is
always well below the European limit values. In the
circulating air, ozone automatically splits into oxygen and
hydrogen within a short time. It is possible that you will
notice the ozone-typical odor when there is a high level of
air pollution. However, this disappears after a short time.
Instructions for use
The noise level of the UVCARE® is very low at approx. 25
dB (A). However, people can feel disturbed by the noise of
the fan in a completely quiet environment.
If you notice any side effects, please inform the
manufacturer specified in these instructions for use.
7. More information
UVCARE® disinfection lights adhere to an extremely strong
UVC lamp. Never look directly into the light source and
never expose the skin of humans or animals to the light
source unprotected, otherwise the cells can be severely
damaged.
UVCARE® is not a complete replacement for protective
masks and other hygiene measures, but complements
them accordingly.
UVCARE® is available in different UVC strengths, sizes and
power consumption. The exact version can be found on
the nameplate oft he UVCARE®.
UVCARE® must be disposed of in accordance with local
regulations.
Housing protection class IP 20
electrical connection
220-240 V 50/60 Hz
Power
33 W/h
Electrical protection
5 A
Manufacturer / distributor / replacement items
Schmelter LED-Technology GmbH
Schmelter UVCARE®
Wiemecker Feld 14 * D-59909 Bestwig-Germany
Tel: 0049-2904-711600 Fax: 02904-71160-29
info@uvcare.de * www.uvcare.de
Information as of march 2021