General Features; Technical Data - Genius JA510C Instrucciones Para El Uso

Control board for rolling gates
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION
This microprocessor control unit for rolling gates performs all the gear unit and safety device control
functions during rolling gate opening and closing operations. The main settings and operating modes
can be defined using dip-switches.
3 built-in LEDs constantly display the status of controls and safety devices.
Power supply voltage
Absorbed power
Max. motor load
Max. load on accessories
Ambient temperature
Protection fuses
Operating logic
Opening/closing time
Pause time
Terminal board inputs
Radio control connector
Terminal board outputs
Housing dimensions
Housing degree of protection
3.1
TERMINAL BOARD M4
3.1.1 Mains
Terminals "1-2" (Phase-Neutral). Power supply voltage 230 V~ - 50/60 Hz
3.2
TERMINAL BOARD M1
3.2.1 Flasher
Terminals "3-4" (Phase-Neutral). Use a flasher with operating voltage 230 V~
3.2.2 Gear unit
Terminals "5-6-7" (Close-Common-Open). Connect the gear unit.
Notes:
1) To install electric cables, us adequate rigid and/or flexible tubes.
2) Always separate the low-voltage connection cables from the 230V~ power supply cables. Cables
for the power supply to the equipment must have a 1.5 mm
separate sheathes.
3) The box features 2 break-through holes Ø35 where Pg21 cable clamps with minimum protection
degree IP54 must be mounted (not supplied).
3.3
TERMINAL BOARD M2
3.3.1 Stop
Terminals"8-9" (Circuit Normally Closed). The status of this input is displayed by LED 1. This circuit is
connected to any device (e.g. button, pressure switch, etc.) which, when a contact is opened, stops
the rolling gate motion. It can be used as a safety on the opening motion.
Note: If STOP devices are not connected, jump connect the input. To install multiple STOP devices,
connect the NC contacts in series.
CONTROL BOARD FOR ROLLING GATES

1. GENERAL FEATURES

2. TECHNICAL DATA

3. CONNECTIONS
230 V~ (+6 -10%) - 50/60 Hz.
1100 W
1150 W
500 mA
-20°C +50°C
Step step / Automatic
60 sec. max
Adjustable with dip-switch
START / STOP / Closing photocell /
Mains power supply
Radio receiver boards
24 Vdc accessory power supply /
Flasher / Motor
80 x 150 x 195 mm.
section. To avoid interference, us
2
5
ENGLISH
3
IP54

Publicidad

Tabla de contenido
loading

Tabla de contenido