The outdoor unit must be installed in such a way, so as to
prevent short circuit of the hot discharged air or obstruction to
the smooth air flow. Please follow the installation clearances
shown in the figure. Select the coolest possible place where
intake air temperature is not greater than the outside air
temperature (Refer to operating range).
Installation clearances
Dimension
Minimum Distance, mm
Note: If there is any obstacle higher than 2m, or if there is any
obstruction at the upper part of the unit, please allow more
space than the figure indicated in the above table.
Downloaded from
www.Manualslib.com

Indoor Unit

Front panel
50mm or more from walls
(on both sides)
Air filter

Outdoor Unit

INSTALLATION OF THE OUTDOOR UNIT
A
B
300
1000
manuals search engine

INSTALLATION DIAGRAM

75mm or more from ceiling
Service lid
M4 x 12L
Opening service lid
Service lid is opening/
closing type.
Opening method
1) Remove the service lid
screws.
2) Pull out the service lid
diagonally down in the
direction of the arrow.
3) Pull down.
C
D
300
500
1 5
Caulk pipe
hole gap
Cut thermal insulation pipe to an
with putty.
appropriate length and wrap it with
tape, making sure that no gap is left
in the insulation pipe's cut line.
Wrap the insulation pipe
with the finishing tape
from bottom to top.
A
B
C
H/2
D