Installation; General Preparation - Dru 55CB Instrucciones De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Installation

General preparation

Please check the appliance immediately after
delivery for damage during transport or any other
damage or defects. The appliance is attached to
the pallet with screws at the bottom.
If you detect transport damage or any other
damage or defects, do not use the appliance
and notify the supplier.
Remove removable parts (fire-resistant inner
plates, fire grate, top plate, ashtray) from the
appliance before starting installation.
It is easier to move the appliance and to avoid
damage if the removable parts have been
removed.
Note the location of the removable parts, so
that you can re-position the parts in the correct
place later on.
1. Open the door; see the following figure:
Subject to change because of technical improvements
2. Remove the fire-resistant inner plates; see the
3
2
1
09-20021-050
1 fire compartment base
2 ash removal port
following figure:
a. Remove the fire basket (6).
b. Raise the baffle plate (5) at the front, pull the
baffle plate 2 cm forwards and allow the baffle
plate to drop down at the back
c. Remove the inner plates on the left and right
sides (4).
d. Remove the inner plates on the back (3).
Vermiculite inner plates are light and tend
to be ochrous in colour on delivery. They
insulate the combustion chamber to boost
combustion.
5
3
4
2
6
1
7
Removable internal parts
09-20021-052
3
4
09-20008-004
9

Publicidad

Tabla de contenido
loading