Remote Control Management; Memory Test; Procedure For Total Deletion Of The Memory; Procedure For Self-Teaching Of The First Remote Control - Aprimatic UNICO Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5. REMOTE CONTROL MANAGEMENT

5.1 Memory test

Power supply
Buzzer
ON, after a brief pause during which the memory is scanned, the buzzer emits
a certain number of beeps (from 1 to 10) to indicate the percentage of the
memory which is free: each beep corresponds to approximately 10% free
memory (10 beep = 100% free memory).

5.2 Procedure for total deletion of the memory

1. Power down the receiver.
2. Power up the receiver again, holding down the delete button (see
figure 1). Release the button when both the LED and the buzzer have
gone OFF.
3. You must now wait until the deletion operation is completed. When it is
completed, the unit will run the memory test.
Power supply
(delete) button
Buzzer

5.3 Procedure for self-teaching of the first remote control

Button 1
3. Press all the buttons on the first remote control you want to add at the same
time (2 buttons for TR2 units, 4 buttons for TR4 units) until both the LED and
the buzzer come ON (continuous beeping) to inform you that the self-
teaching stage is running.
4. Now press any key on the transmitter.
5. The LED and the buzzer go OFF briefly and then come back ON, confirming
the self-teaching of the remote control within the receiver memory.

5.4 Procedure for self-teaching of other remote controls

When the self-teaching of the first remote control is completed, while the
signal is still ON, you can add other remote controls by repeating steps
3 and 4.
Afterwards, you can start the remote control saving procedure again by
pressing, at the same time, all the buttons on a TX which has already been
saved: the buzzer will sound and you can now add extra remote controls by
repeating steps 3 and 4.
All the information about the remote controls is
saved in the removable memory module: every
time the receiver is turned ON, a test is run
automatically to establish which part of the
Memory free
memory is available for the addition of extra
signal
remote controls. When the receiver is turned
Button 2 Button 1
Button 3
Deletion
command
Button 2
Button 4
- 13 -
Deletion
Memory free
phase
signal
1. Power up the receiver.
2. Make sure that the
memory is completely
free (10 consecutive
beeps); if not, delete the
memory.

Publicidad

Tabla de contenido
loading

Tabla de contenido