e
l e c t r i c a l c o n n e c t i o n s
Electrical wiring must be installed by a qualified
professional technician.
An Idm<30 mA residual current device and a safety
device against overcurrent, corresponding to the
connection line characteristics, must be used to pro-
tect the power supply to the towel heater, in conform-
ity to standards in force.
Make sure the mains voltage effectively corresponds
to the one shown on the appliance, before use.
r
a n g e a n d d i m e n s i o n s
Models
FSE045EC
FSE070EC
Power
Height
150 W
450 mm
300 W
700 mm
Width
This towel heater is fitted with class 1 immersion
heating element in water and glycol and must be
earthed.
The three cables must be coupled up in a terminal
box conforming to standards in force, or by using a
Schuko plug.
Single phase power supply 230 V~ 50Hz:
- Blue wire: Neutral
- Brown wire: Phase
- Green and yellow wire: Earth lead
Width
500 mm
500 mm
Depth
Nr. of tubes
110 mm
8
110 mm
13
Depth
8