Fill the trough with fresh incoming water.
13. Place the switch to the "ON" position and replace or close the panel. Discard the first two ice harvests.
REPLACING CONTROL BOX AND TEMPERATURE SENSOR
•
Remove the rear cover and the front or side panel.
•
Locate the electronic control box in the unit.
•
Carefully pull out the temperature sensors (one at the evaporator, another at the condenser).
•
Loosen the screws holding the control box and replace. Reverse the previous steps to reassemble.
•
If you need to replace a temperature sensor, pull out the sensor, open the panel of the control box, pull out
the other end of the sensor and replace. Reverse these steps to reassemble.
REPLACING THE WATER PUMP
•
Turn the unit off and unplug it from the socket.
•
Remove the front cover.
•
Unplug the lines connected with the water pump, including the water outlet tube.
•
Loosen the screws. Replace the pump with a new one.
•
Reverse the above steps to reassemble.
REPLACING THE COOLING SYSTEM COMPONENTS
To replace the condensing components, see the Cooling System figure.
•
Remove the top panel and left
panel, locate the compressor, take
off the clip and replace the defective
components.
•
Reverse the above steps to
reassemble.
ELECTRICAL SHOCK HAZARD
•
Turn the unit off and unplug it form
the socket.
•
If the compressor needs to be
replaced, remove the top cover and
locate the compressor.
•
Unplug the lines and remove the
ground line, open the Process/Suction, remove the refrigerant, take out the compressor and replace it.
•
Reverse the above steps to reassemble.
REPLACING THE FAN MOTOR AND FAN BLADE
•
Remove the top and right panels.
Maintenance
11