Eu Declaration Of Conformity; After Use - Proxxon SP / E Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Proxxon_SP_E
19.11.2005
Never run the grinding wheels without the protection
hoods.
8. Reattach the lateral covers and fasten them securely.
Danger !
Danger of injury !
Before the first use run the grinding wheel for approx. 5
minutes without any load at highest speed. During this time
leave the danger area.
Maintenance
Attention !
Spare parts must only be installed by a specialist.
Proxxon does not assume liability for damage caused by
the unprofessional replacement of spare parts.
Attention !
Before any service or cleaning work pull the mains plug
out.

After use

1. Pull the drawer 6 ( Fig. 1 ) out to side and empty it.
2. Clean the unit with a brush or a soft cloth from all
grinding dust. Make sure that all ventilation slots are free
and unrestricted.
Cleaning
Caution!
Always disconnect the mains plug before doing any
cleaning, setting, maintenance or repair works!
Note: The machine is mostly maintenance free. For a
long service life, the device should be cleaned after
every use with a soft cloth, hand brush or a soft brush.
Even a vacuum cleaner can be recommended.
External cleaning of the housing can be carried out using a
soft, possibly moist cloth. While doing so, a mild detergent
or other suitable cleansing agent can be used. Do not use
solvents or cleansing agents containing alcohol
(e.g. benzene, cleaning alcohol, etc.) as these can corrode
the plastic housings.
13:39 Uhr
Seite 9
Disposal
Please do not dispose of the device in domestic waste!
The device contains valuable substances that can be
recycled. If you have any questions about this, please
contact your local waste management enterprise or
other corresponding municipal facilities.
We declare with sole responbibility that this product fulfils
the requirements of the following EC guidelines:
EC-Low voltage guideline 73/23/EEC
• DIN EN 61029-1 / 12.2003
EC Machine guideline 98/037 EEC
• DIN EN 61029-1 / 12.2003
EC Electromagnetic compatibility guideline
89/336/EWG
• DIN EN 55014-1 / 09.2002
• DIN EN 61000-3-2 / 12.2001
• DIN EN 61000-3-3 / 05.2002
• DIN EN 55014-2 / 08.2002
01.04.05
Dipl-Ing. Jörg Wagner
PROXXON S.A.
Equipment Safety Division
EU-Declaration of conformity
- 9 -

Publicidad

Tabla de contenido
loading

Tabla de contenido