Festo DPA Serie Instrucciones De Utilizacion página 17

Ocultar thumbs Ver también para DPA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
DPA−...
Pneumatic installation
Please note
Incorrectly dimensioned tubing cross−sectional areas can impair the timing
behaviour of downstream switched components.
S Use silencers in accordance with the section Accessories".
The product will then function correctly and reliably.
Use the minimum tubing cross−sectional area as per Fig. 7.
S
Smaller sizes minimize the flow of the DPA−...
Use the manometer kit type DPA−...−MA−S ET.
S
In this way, the output pressure generated can be regulated.
Check whether a pressure compensation reservoir type VZS−... is necessary.
S
In this way you will avoid fluctuations in pressure.
Connect the tubing to the compressed air connections as per Fig. 7.
S
With an output pressure greater than 10 bar, make sure that the permitted
limits for the connecting elements used at output 2 are observed
(if necessary connect the tubing to the DPA−...).
Festo DPA−... 0510c English
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dpa 40Dpa 63Dpa 100

Tabla de contenido