Checking The Primary Air Of The Main Burners; Specification Table; Provisions For Transformation And Installation For Other Types Of Gas; Minimum Adjustment - Lotus CPM-6G Guia Para La Intalación E Instrucciones De Uso

Cuecepasta a gas para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CHECKING THE
PRIMARY AIR OF THE MAIN BURNERS
All burners are equipped with special injectors which do not require the adjustment of the primary air.

Specification table

Mod. CPM - 6G
Burner 13,5 kW max. - 5,2 kW min. 28 mbar
Burner injector 1/100 mm.
Minimum adjustment 1/100 mm.
Pilot injector
Consumption
PROVISIONS FOR TRANSFORMATION AND INSTALLATION FOR OTHER TYPES OF
GAS
All our appliances are inspected and set for liquid gas (see data plate on the inside).
Any transformation or adaptation to other types of gas must be carried out only by a skilled technician. Nozzles for the various
types of gas are contained in the small bag supplied and are marked in hundredths of mm (see Specification table).
MINIMUM ADJUSTMENT Fig.A
After tranforming the appliance for another type of gas, the minimum flame must be adjusted by turning screw (3) to the right
or left until the minimum thermal power measures 5,2 kW.

Substitution of the Main Burner Nozzles

In order to gain access to the appliance it is necessary to open the cabinet doors and remove the front protection, then
loosen the screw fittings.
With a suitable spanner, unscrew the nozzle (22) and substitute it with the appropriate one (refer to Specifications table).

Substitution of the Pilot Burner Nozzles

The flame of the pilot burner has fixed air flow. The only step necessary is the substitution of the nozzle (4) according to the
type of gas. To do this, remove thefront protection as specified above, unscrew the connection (5) with the appropriate spanner,
and substitute the nozzle (4) with an appropriate one. With the correct nozzle, the flame must lick the thermocouple.
Important!
After transformation to another type of gas, the data plate specifications must also be changed to the type of gas for which
the appliance is now set up.

CHECKING APPLIANCE OPERATION

Instructions for use are supplied with the appliance.
Check for any gas leaks.
Check the pilot flame; it should be blue and lick the thermocouple, otherwise the pilot burner nozzle must be checked.
Check ignition and the main burner flame.
The appliance should always be used according to the instructions supplied.

MAINTENANCE

With prolonged use it is necessary to carry out regular maintenance on the appliance to ensure its safe functioning. To this
end, a maintenance contract is recommended. The maintenance must be carried out only by skilled technicians who are
familiar with the standards of the country where the appliance is installed.
GB
IE
12.8 kWh/KG
12.8 kWh/KG
G30
G31
BUTANE
PROPANE
37 mbar
185
185
100
100
30
30
kg/h 1,054
kg/h 1,054
Fig.A
Fig.A
27
9.45 kWh/m
st.
3
G20
NATURAL GAS H
20 mbar
280
adjustable
51
m
st./h 1,428
3