FEED WATER CHARACTERISTIQUES
The water physical-chemical characteristics are very important for the proper operation and the durability of the boiler or thermo-stove.
Among the consequences inconvenient caused by the low quality of the feed water, the most frequent consequence is the incrustation in the
thermal exchange surfaces.
It is also known that calcareous incrustations reduce the thermal exchange, even with a few millimetres, causing that some localised heat
spots are harmful. It is strongly recommended to do a water treatment in the following cases:
a.
The maximum water hardness must not exceed 60 mg/l.
b.
Very large installations.
c.
Consecutive fillings caused by maintenance works of the installation or produced by loss.
For the treatment of the feed water of the thermal installation it is recommended to ask for an authorised fitter.
•
FILLING THE SYSTEM
When the hydraulic connections are finished you can connect the system.
Open all the air vent valves of the radiators, thermo-stove and installation.
WARNING!! The thermo-stove is provided with an automatic air vent valve. Make sure all the air vent devices are placed in the highest
of installation because it might not be enough. Do not forget to purge the circulating pump.
Open the fill tap gradually making sure that all the air vent valves work normally. Control the installation is under pressure by using a gauge.
Pressure must be between 1.1 and 1.2 bars with an installation provided with a closed tank. Close the fill tap and purge again the air on the
boiler through the air vent valve.
It is compulsory that each installation is equipped with a back end protection valve (thermal shock valve)to permit uniform
temperatures at the start up of the boiler or thermo-stove and to avoid condensation inside the combustion chamber.
Bronpi approved Distributors can supply such a valve.
7
STARTUP
The ignition of this kind of equipments is automatic, so, please do not put on the burner any kind of material to ignition.
It is forbidden to use liquid substances such as alcohol, gasoline, petroleum or similar products. The use of this substance
leads the loss of warranty.
Before the ignition, follow the next verifications:
-
The electrical cable must be connected to the electrical network (230 Vac) with a socket equipped with earthing system.
-
The bipolar switch, placed on the rear side of the thermo-stove, must be in position I.
-
The pellet tank must be supplied.
-
The combustion chamber must be clean.
-
The burner must be clean and properly placed.
-
The combustion chamber door must be closed correctly.
During the first ignition could happen that the thermo-stove has finished the ignition cycle and there is no flame. In this case the thermo-stove
automatically starts an alarm state. This happens because the fuel feeder is empty and needs a moment to fill in. To solve this problem start
again the thermo-stove (taking into account the previous considerations) until the flame appears.
The thermo-stove, at the beginning, must be subject to different start-up cycles so that all materials and the paint can complete different
elastic expansions.
At the beginning, it is possible that you note smoke or smell which are typically produced when metals are subject to high temperatures or
when the paint is still fresh. This paint is boiled at 80º C for a few minutes when construction, but it must exceed for a time the temperature of
200 ºC before the adhesion to the metallic surfaces.
Therefore, it is important to adopt these measures during the ignition phase:
1.
Assure that there is a good air refill in the place where the equipment is installed.
2.
During the firsts ignitions, keep a low power work and the oven lit during at least 6-10 hours continuously.
3.
Repeat this operation at least 4-5 times or more, depending on the needs.
4.
During the first ignitions, you should not place any object on the equipment and, in particular, on lacquered surfaces. Lacquered
surfaces should not be touched while the equipment is heated.
8
SERVICING AND CARE
The maintenance operations guarantee a proper working of the product over
its lifetime. Not making these maintenance operations will affect the security
of the product.
8.1
BURNER CLEANING
The burner cleaning must be made daily (see drawing D13).
•
Remove the burner from its place and clean the holes.
•
Use a vacuum to clean the ashes in the burner. You can buy a Bronpi vacuum-cleaner in the same Bronpi distributor where you
bought your stove.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
29
D13
HYDRO SERIES