WARNING Fire and explosion hazard!
The unit is not permitted to be used for the extraction of
inflammable gases.
The unit must not be exposed to temperatures above
50°C, naked flame or condensed solvents.
The organisation operating the unit is responsible for the
observance of the legal limits for noxious substances at
the place of work.
The filtration system may only be put into operation if it is
in perfect working order.
Intended use of the soldering station/ desoldering station
also includes the requirement that you
•
adhere to these instructions,
•
observe all other accompanying documents,
•
comply with national accident prevention guidelines
applicable at the place of use.
The manufacturer will not be liable for unauthorised
modifications to the device.
User groups
Due to differing degrees of risk and potential hazards,
several work steps may only be performed by trained
experts..
Work step
Replacing electrical
replacement parts
Specification of
maintenance intervals
Operation
Filter change
Operation
Notice
The unit may emit dust from the main filter after
transportation. Make sure that the unit is put into service in a
suitable room.
CAUTION! A high noxious gas concentration will cause
the activated charcoal to heat up. To avoid overheating, the
unit should be run without noxious gases for several minutes
before switching off.
Put the tool into operation as described in the chapter
„Placing into operation".
Please adhere to the operating instructions of the connected
devices.
Check to see if the mains voltage matches the ratings on the
nameplate.
Make sure the machine is switched off before plugging in.
Optimal gas filtration is achieved as follows:
•
Temperature of process air in gas filter < 38 °C
User groups
Electricians
Technical trainees under the
guidance and supervision of
a trained expert
Safety expert
Non-specialists
•
Relative humidity < 60 %
•
Gas molecules > 30 g/mol (better filtration results are
achieved with larger molecules)
•
Boiling point of the gas molecules > 0 °C
Use a broadband gas filter (without a suspended matter
filter) for the extraction of adhesive vapours.
Care and maintenance
WARNING
Before doing any work on the machine, pull the plug out
of the socket.
The operator must check that the connector is still removed
at every station to which they have access.
The unit must not be altered or modified in any way!
Repairs must always be referred to a Weller-trained
specialist.
Use original replacement parts only.
Filter change
The suspended matter filter and the
MIN 1x
broadband gas filter are complementary
to one another and can be replaced
together as a compact filter. The fine
dust filter (filter mat) is the preliminary
year
stage of the compact filter and therefore
must be replaced more frequently.
It is strongly recommended that the
compact filter be replaced after no more
than 10 fine dust filter changes.
To ensure that the filtration system functions properly, the
compact filter must be replaced as follows:
•
at least once a year or
•
if the maximum allowable workplace concentration is
exceeded or
•
as per maintenance schedule
Contaminated filters must be treated as special waste. Wear
suitable protective gear.
Notice
Different fluxes and flux constituents and the amount of and
size of dust particles in the extracted air will signifi cantly
effect the filters working life.Submicron particles in the
extracted air increase when soldering or welding to varnish
insulated wire.
EN
ENGLISH
15