TROUBLESHOOTING

PROBLEM
1. The gas cylinder is frosted over.
2. The openings are blocked.
3. The control knob is not in the "ON"
The burner will not
position.
ignite.
4. There may be too many lava rocks
covering the burner bowl or small pieces
may be blocking the burner ports.
The burner flame
1. The gas pressure is low.
is too low.
2. The cylinder is less than 1/4 full.
1. There is dirt or film on the reflector and
Carbon build-up
burner screen.
and/or thick black
2. The burner is blocked.
smoke is present.
POSSIBLE CAUSE
CORRECTIVE ACTION
1. Wait until gas cylinder warms up
and becomes unfrosted.
2. Clear the blockage.
3. Turn the control knob to the "ON"
position.
4. Remove a portion of the lava rocks.
Make sure the lava rocks just cover
the upper surface of the burner.
1. Turn the cylinder valve off and
replace the cylinder. Check the
burner ports for blockage.
2. Use a full gas cylinder.
1. Clean the reflector and burner
screen.
2. Remove any blockage and clean
the burner inside and outside.