Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with unvented room heater.
3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
an unvented room heater.
This appliance may be installed in an aftermarket* permanently
located, manufactured (mobile) home, where not prohibited by
state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases.
General Information
This appliance is design certified in accordance with American
National Standards Institute Z21.11.2 by the Canadian Standards
Association Laboratories as an Unvented Room Heater and shall
be installed according to these instructions.
Any alteration of the original design, installed other than as shown
in these instructions or use with a type of gas not shown on the
rating plate is the responsibility of the person and company making
the change.
This appliance is equipped for (natural gas or propane) gas.
Field conversion is not permitted.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Model
Input BTU/HR (KW/H) Five Plaques
BTU/HR (KW/H) Three Plaques
BTU/HR (KW/H) Two Plaques
BTU/HR (KW/H) One Plaque (Nat. Gas)
BTU/HR (KW/H) One Plaque (LP Gas)
Height
Width
Depth
Gas Inlet
Accessories
Blower
Floor Stand*
*
Floor stand can not be used in a bathroom or bedroom installation. SR-6 must be wall mounted in a bathroom or bedroom installa-
tion.
*
Floor stand can not be used in a bedroom installation. SR-10 must be wall mounted in a bedroom installation.
The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFPA54 defines an unconfined space as "a space whose vol-
ume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m
space."
16942-9-0314
INTRODUCTION
WARNING
SPECIFICATIONS
SR-6
6,000 (1.8)
6,000 (1.8)
22" (559mm)
11 7/8" (302mm)
6 1/2" (165mm)
3/8" (10mm)
SRS-10
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating
value. Contact the manufacturer or your gas company before
changing spud/orifice size.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equipment
shall be performed only by a qualified agency. The term "qualified
agency" means any individual, firm, corporation, or company that
either in person or through a representative is engaged in and
is responsible for (a) the installation, testing, or replacement of
gas piping or (b) the connection, installation, testing, repair, or
servicing of equipment; that is experienced in such work; that is
familiar with all precautions required, and that has complied with
all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural
gas-fired space heaters shall be prohibited in bedrooms and
bathrooms.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m) ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changing spud/orifice size.
SR-10
—
—
—
—
—
—
10,000 (2.9)
10,000 (2.9)
22" (559mm)
11 7/8" (302mm)
6 1/2" (165mm)
3/8" (10mm)
—
—
SRS-10
per kw) of the aggregate input rating of all appliances installed in that
3
SR-18
SR-30
—
30,000 (8.8)
18,000 (5.3)
18,000 (5.3)
12,000 (3.5)
6,700 (2)
8,000 (2.3)
6,700 (2)
7,000 (2.1)
22" (559mm)
22" (559mm)
18" (457mm)
24 1/8" (613mm)
6 1/2" (165mm)
6 1/2" (165mm)
3/8" (10mm)
3/8" (10mm)
SRB-18
SRB-30
SRS-18
SRS-30
—
Page 5