FILTER REPLACEMENT
Filter replacement varies according to the use and frequency of use of the machine.
The clogging/build up of dirt on the filters may vary according to :
• Welding material (every material generates different fumes/powder)
• Welding type (each process such as MIG, TIG, electrode, etc....)
• Elements in contact (for example oil, grease, paint, etc. which generate more «agressive» fumes).A
To replace the filters, a triangle key (FIG II) is necessary. This key is supplied with the machine, which opens the filters'
inspection panels.
Opening that panel allows direct access to the filter section. Removing the filters is done by pulling them one by one
towards the outside.
Note that the filtering section may be difficult to remove due to the seals which are set up around the filters. These
hermetic seals (which are pressurised) guarantee the optimal filtering of the extracted particules.
Removing the filters must be done in the following order, starting with the lowest filter; which has a frame that can
be used as a bearing point in order to remove the filter. The other filters can then be removed easily as they are not
pressurised anymore.
FILTER DETAILS
First filtration step : Metal filter (Clean once a week))
Dimensions
Filtration material
Can regenerate
Behaviour under flame
Second filtration step : Ondulated filter cell (Clean once every 2 weeks)
Dimensions
Filtration material
Can regenerate
Behaviour under flame
TROUBLESHOOTING
PROBLEM
STARTING PROBLEM
NO STARTING
THE MACHINE ABSORBS MORE CUR-
RENT THAN SHOWN ON THE PLATE/
INSTRUCTION MANUAL
EXCESSIVE VIBRATION
REDUCED SUCTION
10
FUME EXTRACTOR EVO 2.1 RE (230V)
+ ARM 160/3
mm
mm
Low power supply voltage
No power supply
No power supply
Engine fatigue
Engine rotates at low speed
Moving parts out of balance
Faulty anti vibration system
Obstructed filters
Air leak
Turbine out of balance
485x485
Aluminium fiber
Yes (washable)
Non-flammable
490x592
Polyester fiber
Yes (shaking)
DIN 53438 F1
CAUSE
Check the plate and the power sup-
ply.
Check the connection to the mains
and/or the socket
Check the connection to the mains
and/or the socket
Replace the extraction fan
Check the power supply.
Check the engine.
Check the moving parts
Check the fixation of the anti vibra-
tion systems and that they operate
properly
Check the filters' state of health
and the control panel. If necessary,
replace the filters.
Check the coating. If possible, repair
with silicone.
Check the turbine and the cleanliness
of the blades. Remove the fan and
clean the blades thoroughly.
EN