Remedy Of Faults; Wearing Parts - Oase FP 1500 Manual De Instrucciones

Ocultar thumbs Ver también para FP 1500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
- GB -
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
If necessary, clean the unit with clear water using a soft brush.
− Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
− In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
Cleaning the unit
Open strainer casing and remove pump (B). Unscrew pump lid and remove impeller. Clean all components using clean
water and a brush.
After cleaning the pump, reassemble in the reverse order. Insert pump in the strainer casing. Regarding the 1500-2500
series of the filter pump, ensure correct seating of the rubber buffers used for the bearing of the pump. Route connecti-
on cable such that it cannot be pinched. Refit strainer lid and close.

Remedy of faults

Malfunction
The unit is not operating
Insufficient delivery rate
Unit switches off after a short running period
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!

Wearing parts

The rotor is a wearing part and is, therefore, not covered by our warranty.
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
8
14834-08-13_GA_FP 1500-3500_DE.p8 8
Cause
No mains voltage
Impeller blocked
Strainer casing clogged
Excessive pressure losses in the hoses
Water temperature too high
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Note maximum water temperature of +35 °C
02.08.2013 12:11:11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fp 2500Fp 3500

Tabla de contenido