To purchase a Natural Gas Conversion Kit call Sears at
1.800.4.MY.HOME ®
Natural gas conversion kit
Kenmore Model # 10478
(Manufacturer Part No.: 2818-2T-KIT)
Your grill can be converted to natural gas with this
conversion kit by a qualified gas technician only. In order
to convert this grill the technician will need this
conversion kit.
The kit contains orifices for various grill models. Please
select the orifices as listed below and discard the rest.
Follow the conversion instruction provided with the kit.
Natural Gas Connection Preparation:
1. Turn off gas supply, and then remove cap on gas
supply side.
2.
Recommended: Install a shut-off valve on
gas supply side before installing the socket.
3. Socket should be installed by an authorized
technician in accordance with the national fuel gas
code (NFPA54/ANSI223.1).
4.
Before inserting plug, turn on gas supply and leak
test all connections including the stem of the shut-off
valve and the opening of the socket. For best results,
use an ammonia-free soap & water solution.
Operating Instructions:
1. To connect, push back socket sleeve.
Model
Main Burner 1.37 mm
148.16154211
4
12 ft. extension hose with 3/8 in. ID (inner diameter)
If converting the grill to natural gas, the technician in
most cases will need this 12 ft. extension hose with 3/8"
ID (inner diameter), which is included in the natural gas
conversion kit.
2. Insert plug and release sleeve.
3. Push plug until sleeve snaps forward. (Gas will flow
automatically.Failure to connect plug properly to
socket will inhibit gas flow to the appliance.)
Socket
Sleeve
\\\\
To disconnect
1. Pull Sleeve back. Pull plug out of socket. (Gas is
automaticallyshut off.)
2. Close shut-off valve or turn off gas supply, and
replace dust caps on socket and plug.
Gas Requirements
LP Gas
Now that your grill is converted to Natural Gas use, it is
set for 7-inch water column (WC) pressure, and cannot
be used with Propane Gas. The factory-supplied
regulator and hose must be used with a 20-lb. LP gas
tank.
11