IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "installers of elec-
trical equipment" and must respect the local standards and regulations in
force. All materials used must be approved and must suit the environment
in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has
been made. "i.e. for the automation of hinged gates" with one or two gate
leaves.
• The unit may be fitted both to the right and to the left of the passageway. This
product and all its relative components has been designed and manufactured
by Cardin Elettronica who have verified that the product conforms in every
aspect to the safety standards in force.
Any non authorised modifications are to be considered improper dangerous
and the complete responsibility of the installer.
Caution! mechanical stop buffers must be installed in both the open-
ing and closing positions (pos. 1, 2, 3, fig. 5).
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property and not on the
public side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be
situated at a height between 1,5 and 1,8 m in a position where the operator
can see the gate at all times.
5) At least two warning signs (similar to the example on the
right) should be placed, where they can be easily seen by
the public, in the area of the system of automatic operation.
One inside the property and one on the public side of the
installation. These signs must be indelible and not hidden by
any objects (such as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or
pets must not be allowed to play within the area of a gate
installation. If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within ≤ 500 mm of a fixed structure
the space must be protected by an anticrush buffer (fig. 1, detail 11).
8) You are advised to protect the sistem's lateral access points with pairs of
(FTCS) photocells connected to the stop input, see installation example,
component 14 on page 2.
9) If you have any questions about the safety of the gate operating system, do
not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
200/BL224E The operator is suitable for automating hinged gates (up to 2,2
m in length and 200 kg in weight per gate leaf) and consists of a compact and
tenacious appliance that is isolated inside a waterproof compartment and is
lubricated using permanently fluid grease. If used with the maximum travel
distance an opening angle of 90° and the addition of an electric locking device,
it can be used for gates up to 3,5 m in length and 150 kg in weight.
• Single piece geared motor held together by a solidly built three piece carter.
• Drive motor maximum 28 Vdc with an incorporated encoder
• Self-locking geared motor with a watertight container in extruded aluminium
containing cyclic train gears. Rotation is supported by a system of double
bearings.
• The release mechanism that guarantees emergency manoeuvring is
extremely efficient under all working conditions and is protected by a solid
shock-proof plastic carter. Opening is obtained by inserting the key and
sliding the cover backwards.
• The terminal board (wired up using Cardin cable CABPC10) is located in a
special compartment fitted with a cable clamp and a protective cover.
• The covering components are finished in spray painted aluminium.
• Fine adjustment brackets and accessories in zinc-plated steel.
ACCESSORIES
980/XLSE11C - Electric locking device 12 Vac
IMPORTANT REMARKS
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and
will be dealt with according to the laws and standards of the individual
member nation.
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger. During blackouts the gate can be
released and manually manoeuvred using the supplied release key (see manual
release page 4). Periodically check the moving parts for wear and tear and grease
if required, paying particular attention to the never ending screw pos. 10 fig. 2,
using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of -20 to +70°C.
Periodically check the correct operation of all safety devices (photoelectric cells
etc.). Eventual repair work must be carried out by specialised personnel using
original spare parts. The appliance is not suitable for continuous operation
and must be adjusted according to the model (see technical data on page 48).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside
the opening range of the gate.
Before starting the installation of the system check that the structure which is
WARNING
to be automated is in good working order and respects the local standards and
AUTOMATIC OPENING
regulations in force. To this end make sure that the gate is sufficiently rigid (if
KEEP CLEAR
necessary reinforce the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
CHILDREN OR PETS MUST NOT
• Check the safety measures between the fixed and moving parts:
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds 30 mm throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order (the
upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control devices
fitted and make sure the system conforms to the local standard and regula-
tions in force (see installation example fig. 1 page 2).
• Check that the appliance is suitable for the size, weight and duty cycle of the
gate to which it is to be applied (see duty cycle on page 48).
ASSEMBLY PROCEDURE
The unit may be positioned to the right or to the left of the passageway.
• Move the gate/s to the closed position.
• According to the dimensions of the column choose the length of the attach-
ment bracket: complete rear attachment bracket (supplied with a ferrule
inserted at 145 mm) or a reduced bracket of 105 mm obtained by transfer-
ring the rotation ferrule to the first hole (fig. 7a) and then cutting the bracket
at point "A" figure 7.
• Fasten the rear mooring bracket to the column (fig. 7 page 5), taking into
account the measurements "A" and "B", after having checked the position
of the gate hinge with respect to the column (measurement "C" fig. 4 page
4) according to the type of opening required.
Note: if the gate brackets are to be pre-installed (front and rear) without the
presence of the piston, you must also consult the indications in figure 9.
• Slide off the worm screw protective cover (the screw, lead nut and adjustable
safety rings will now be exposed)
15
IMPORTANT REMARKS
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish.
The user is therefore obliged to either take the product to a
suitable differential collection site for electronic and electrical
goods or to send it back to the manufacturer if the intention is
to replace it with a new equivalent version of the same product.