Important Remarks; Important Safety Instructions; Installation Instructions - Riello Elettronica Cardin HL Serie Manual De Instrucciones

Tabla de contenido

Publicidad

IMPORTANT REMARKS

READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
These instructions are aimed at professionally qualified "installers of electrical equip-
ment" and must respect the local standards and regulations in force. All materials used
must be approved and must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified techni-
cians. Before carrying out any cleaning or maintenance operations make sure the
power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e. for the automation of hinged gates" with one or two gate leaves,
max. length 3 m, max. weight 350 kg.
• The unit may be fitted both to the right and to the left of the passageway.
This product and all its relative components has been designed and manufactured
by Cardin Elettronica who have verified that the product conforms in every aspect
to the safety standards in force. Any non authorised modifications are to be con-
sidered improper dangerous and the complete responsibility of the installer.
IMPORTANT! The geared motor is not fitted with a torque limiter. Only
use an electronic programmer which has a torque limiter with maximum
force at the head of the gate equal to 150 N.

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not on the
public side of the gate. The gates must not swing outwards onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate at all times.
5) At least two warning signs (similar to the example on the right)
should be placed, where they can be easily seen by the public,
in the area of the system of automatic operation. One inside
the property and one on the public side of the installation.
These signs must be indelible and not hidden by any objects
(such as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or
pets must not be allowed to play within the area of a gate
installation. If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least 500 mm of a fixed
structure the space must be protected by an anticrush buffer (fig. 1, detail 11).
8) A correct earth connection is fundamental in order to guarantee the electrical
safety of the machine
9) If you have any questions about the safety of the gate operating system, do
not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
800/HL2524SB
Irreversible geared motor, maximum opening 110°.
806/HLCF1
Embedding case in zinc plated steel with cataphoresis finishing
and a transmission lever for 110°.
806/HLCF1Z
Embedding case in zinc plated steel with transmission lever for
110°.
800/HL1824SB
Irreversible geared motor, gate opening 118°-360°.
806/HLCF18
Embedding case in zinc-plated steel with cataphoresis finishing
and accessories for gate opening 110°-360°.
806/HLCF18Z
Embedding case in zinc-plated steel with accessories for gate
opening 110°-360°.
806/HLCA140
Kit of lever accessories for a 140° opening angle
• Single piece geared reduction unit;
- 24 Vdc drive motor with an incorporated overload protector and a permanently
lubricated reversible reduction unit mounted on a cast iron stator;
- rubber sealing gasket;
- key operated manual release mechanism;
• Embedding case in hot rolled zinc-plated steel
- release unit housing in pressed aluminium
• Transmission levers in zinc-plated steel
- gate fastening bracket in zinc-plated steel.
IMPORTANT REMARKS
USER INSTRUCTIONS
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials. Illicitly disposing of this
product by the owner is punishable by law and will be dealt with according
to the laws and standards of the individual member nation.
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using the
supplied release key (see manual release pag. 7).
Periodically check the moving parts for wear and tear and grease if required
using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of -20 to +70°C. In case of failure or opera-
tional anomalies switch off the power at the mains do not attempt to repair the
appliance yourself.
Periodically check the correct operation of all safety devices (photoelectric cells
etc.). Eventual repair work must be carried out by specialised personnel using
original spare parts. The appliance is not suitable for continuous operation
and must be adjusted according to the model (see technical data on page 20).

INSTALLATION INSTRUCTIONS

The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children and
outside the opening range of the gate.
Before starting the installation of the system check that the structure which
WARNING
is to be automated is in good working order and respects the local standards
AUTOMATIC OPENING
KEEP CLEAR
and regulations in force. To this end make sure that the gate is sufficiently
rigid (if necessary reinforce the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which main-
tain unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the pave-
ment never exceeds 30 mm throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order (the
upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control devices
fitted and make sure the system conforms to the local standard and regula-
tions in force (see installation example fig. 1 pag. 2).
• Check that the appliance is suitable for the size, weight and duty cycle of the
gate to which it is to be applied (see duty cycle on page 20)
FITTING THE UNIT
- Choose the ideal position for the foundation case according to the opening
angle (90°-110°-180° fig. 5) and the position of the gate pivot.
- Place a mechanical travel buffer in the closing direction.
lever for 110°
- Dig the foundation hole "A" (fig. 6) sufficiently large to house the foundation
case and run a drain channel up to the hole "B".
- Run the channelling for the cables up to the hole "C".
- Insert the six round headed screws "E" into the holes on the bottom of the
case and fasten down using the supplied nuts and washers.
- Place the foundation case in the hole with the pin perpendicular to the upper
gate pivot "D", cover the case in concrete and check that it is in square and
that the upper edge protrudes by at least 3 mm from the ground.
11
IMPORTANT REMARKS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differen-
tial collection site for electronic and electrical goods or to send
it back to the manufacturer if the intention is to replace it with a
new equivalent version of the same product.

Publicidad

Tabla de contenido
loading

Tabla de contenido