GENERAL USE & WARNING SYSTEM:
• PowerCap
Infinity
will deliver a minimum 160L/min of filtered air to the user for upwards of 8 hours through a fresh pair of filters.
®
®
• The user may notice changes in motor tone associated with movement, this is a normal operational sound linked to motor construction.
• The array of LEDs at the top of the field of vision is a Head-Up Display (HUD) informing the user of PowerCap
warning scenario table.
• As the battery approaches low remaining charge, the green light will be joined by a flashing red light to inform the user of having
approximately 20 minutes to withdraw from the hazard area to replace/recharge the battery.
• As the battery approaches a fully discharged state, the green light will extinguish and the flashing red light will be joined by a two-tone
buzzer. The user should withdraw from the hazard zone immediately to replace/recharge the battery pack.
• Do not use or store PowerCap
• When the green light is replaced by a blue flashing light and a pulsed buzzer tone, the system is no longer able to deliver sufficient airflow
as the filters have become blocked. The user should withdraw from the hazard zone immediately to check and/or replace both filters.
• PowerCap
Infinity
is rated as IP54 for protection against water and dust ingress. The unit can be used in dusty environments and
®
®
inclement weather conditions. It should not be immersed in water.
USING POWERCAP
INFINITY
®
• Operating temperature should be between +5°C and +40°C and relative humidity not greater than 75%.
• PowerCap
Infinity
offers respiratory protection against spores, fibres, fumes (very fine metallic droplets/particles) and dusts.
®
®
• The visor offers protection against medium energy impacts, short circuit electric arcs, molten metals and hot solids to EN166.
• The EVO5
helmet offers protection against falling objects to EN397.
®
Infinity
at temperatures below +5°C as the battery performance can be affected.
®
®
:
®
7
Infinity
's status. See
®
®