Compliance With Standards; Introducción; Instalación; Memorización - Tyco Visonic KF-235 PG2 Guia Del Usuario

Mando 2 vías powerg inalámbrico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. COMPLIANCE WITH STANDARDS

Compliance with Standards
EN 50131-1
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1)
This device may not cause harmful interference, and
(2)
this device must accept any interference received, including interference that may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Warning!
Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Visonic Ltd.) could void the user's authority to operate the equipment.
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled environment.
APPENDIX: SPECIFICATIONS
Frequency Band (MHz)
Europe and rest of world: 433-434, 868-869 USA: 912-919
For UL Listed product, the KF-235 PG2 operates at 912-919 MHz.
Maximum Tx power
10dBm @ 433MHz, 14dBm @ 868MHz
Battery type
VARTA 3V CR-2032 Lithium battery.
Low Battery Threshold
2.1 V
Battery Life Expectancy
5 years (for typical use)
Power Supply
Type C, EN 50131-6, CR 1001
Operating Temperature
0° to 55°C (32° to 131°F)
For UL Listed product, the Ambient Temperature is 0 to 49°C.
Average relative humidity  75% non-condensing. 30 days / year relative humidity may vary 85 % 95 % non-condensing
Humidity
For UL Listed product, the Relative Humidity is 93%.
Dimensions (LxWxD)
67 x 27.6 x 12 mm (2.64 x 1.09 x 0.47 in.)
Weight (including battery)
25 g (0.9 oz).
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
ES
1. INTRODUCCIÓN
KF-235 PG2 es un mando de dos vías PowerG de 4 botones, diseñado para uso con la familia de paneles de control PowerMaster.
Las características del KF-235 PG2 incluyen armado y desarmado del sistema así como visualización del estado del sistema y operación de una
función programable predefinida. Los comandos son invocados presionando cualquiera de los cuatro botones de mando. El estado es indicado vía
los LED de estado y zumbador después de cada comando.
KP-235 PG2 alerta al panel de control y al usuario cuando su batería está agotada y necesita ser reemplazada.
2. INSTALACIÓN
2.1 Memorización
Remítase a la Guía del Instalador del panel PowerMaster y siga el procedimiento previsto en la opción."02:ZONAS/DISP" del menú de instalador. Una
descripción general del procedimiento se proporciona en el siguiente flujograma.
Paso 1
Pulse el menú de instalador y
seleccione "02.ZONAS/DISP"
02.ZONAS/DISP
D-303486 KF-235 PG2 User's Guide / Guía del usuario / Guia do utilizador
Europe: EN 300220, EN 50131-1 Grade 2, Class II and, EN 301489, EN 50130-4, EN 60950, EN 50131-6, 50131-3, EN
50130-5
Hereby, Visonic Ltd. declares that the radio equipment type KF-235 PG2 is in compliance with Directive 2014/53/EU
The full text of the EU declaration of conformity is available at the following internet
center.
Certified by Norwegian accredited certification body Applica Test & Certification AS in accordance with
6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
has certified only the 868 MHz variant of this product.
Applica T&C
USA: CFR 47 Part 15 (FCC)
Canada: RSS 210
UK: This product is suitable for use in systems installed to conform to PD6662 at Grade 2 and environmental class 2.
DD243 and BS8243
According to EN 50131-1, this equipment can be applied in installed systems up to and including Security Grade 2, Class
II.
Paso 2
Seleccione "AÑADIR DISPOSITIVO"
Vea Nota 1
AÑADIR DISP.
MODIFICAR DISP.
Paso 3
Memorice el mando presionando el
botón
y soltándolo tan pronto
como el LED amarillo se encienda.
Alternativamente, ingrese la ID del
dispositivo (impreso al dorso del
mando)
MEM AHORA o
PULS ID:XXX-XXXX
address: http://www.visonic.com/download-
EN 50131-3, EN 50131-
Paso 4
Seleccione el Número de Mando
deseado para el nuevo mando
F02:Mando
ID No. 301-XXXX
3

Publicidad

Tabla de contenido
loading

Tabla de contenido