UNLOCKING DEVICE
If the gate needs to be operated manually because of a power failure or operator malfunctioning:
Insert the release key to the release slot fig. 7 .
Ÿ
Turn the release key .
Ÿ
Pull out the release bar and keep it pulled out .
Ÿ
Move the gate manually only in the event of a power failure.
INSTALLING THE ELECTRIC LOCK
If you need to install an electric lock, refer to figures
1) ELECTRIC LOCK
2) ELECTRIC LOCK FASTENING PLATE
3) BUSHING
4) END-STOP FOR BUSHING
5) SPRING LATCH
6) THROUGH CYLINDER (ON REQUEST)
7) GATE

FINAL CHECKS

Power the system and run a complete opening and closing cycle checking that:
• The safety devices function properly;
• The gate moves smoothly;
• Good hold of the fastening brackets;
• That the power cable moves freely;
• The gate assembly conforms to EN 12453 and EN 12445;
MAINTENANCE
Periodically check the gate structure, in particular:
Check functioning of the hinges;
Ÿ
Check that the leafs are correctly balanced. Do the test by unlocking the operator and checking that the leafs do not
Ÿ
move on their own;
Check good functioning of the safety devices;
Ÿ
Unlock the operator and check that there are no points of friction along the entire travel;
Ÿ
Periodically check proper adjustment of the operator thrust force and the efficiency of the unlocking device for
Ÿ
manual operation (see the relative paragraph).
The safety devices installed on the system must be checked every six months.
Ÿ
MALFUNCTIONING
For any unresolved malfunction, cut the power to the system and call in a qualified technician (installer). In the
period when the gate is out of service, activate the manual unlocking device to allow manual opening and
closing.
fig.
11 and
fig.
12 .