Installation Instructions
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death�
RISK OF ELECTRIC SHOCK WITHOUT ELECTRICAL GROUNDING
CONNECTION
You must disconnect the neutral from the grounding lead� Connect the
appliance in accordance with local electrical codes�
For model rated up to 4�3 kW connect to a 20 A fuse or circuit breaker�
Please read these instructions. They will save you time and effort and help to ensure
optimum oven performance.
Be sure to observe all WARNINGS. These installation instructions are intended for use by a
qualified installer.
In addition to these instructions, the oven shall be installed in accordance with Canadian
Electric Code C22.1-latest edition/Provincial and Municipal codes and/ or local codes.
These shall be carefully followed at all times.
NOTE: IF INSTALLING YOUR OVEN IN CANADA PLEASE CHECK TO MAKE
SURE THAT YOU HAVE A MODEL WITH THE CANADIAN LISTING
MARK, AS SHOWN ON THE RIGHT.
The means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules�
Electrical Supply
Before installing the oven have a qualified electrician verify that your home is provided with
adequate electrical service and that the addition of the oven will not overload the branch
circuit on which it is to be installed.
A separate 3-wire or 4-wire single phase, 120 V/240 V, 60 Hz, or a 120 V/208 V, 60 Hz
branch circuit is required.
For hook-up of the oven you will need to have an approved junction box installed where it
will be easily reached through the front of the cabinet where the oven will be located. The
oven has 130 cm (51 3/16 in.) of conduit. Allow 130 to 150 cm (51 3/16 to 59 1/16 in.) of
slack in the line so that the oven can be moved if servicing is ever necessary.
DO NOT shorten the flexible conduit.