SWITCH ON the batteries switches (port and starboard engine
compartments) and CHECK that the windlass circuit breaker
is switched on.
Caution - Principle of batteries coupling :
The coupling between the service park batteries and engine bat-
tery is activated when a voltage exceeds 13.2 V.
The coupling is maintained until the park voltage is greater than
12.8 V.
When the voltage drops below 12.8 V, the coupling stops,
the engine battery is then isolated from the park service.
The circuit breaker AID / START enables the coupling of battery
park IF A PARK IS INSUFFICIENT.
It should always be disconnected when the
engine is running.
Fuse boards:
The three fuse boards are positioned as follows:
1 in seat back of the bench square,
1 in the port aft cabin wardrobe,
1 in the starboard aft cabin wardrobe.
The contents of each box is detailed in the cover
DAD_MDP_054_001—10/07/2012
NOT CONTRACTUAL DOCUMENT
ENGAGED
7