6.
Place the lower support bracket on the perforation
diagram making it coincide with the traced triangle,
mark the two external holes and perforate. Remove
the perforation diagram, insert two wall-dowels and
fix the support bracket of the hood with two 5x45
mm screws.
7.
If supplied dismantled, fix the hooks to the side of
the aspiration group with two screws (7a). Hang the
hood onto the lower bracket (7b).
8.
Adjust the distance of the hood from the wall.
9.
Adjust the horizontal position of the hood.
10. Using a pencil mark the cooker hood permanent drill
hole inside the suction group (1 or 2 fixing points are
necessary for permanent mounting).
11. Remove the hood from the lower bracket.
12. Drill at the point marked (Ø8mm).
13. Insert 1 or 2 wall screw anchors according to
requirement.
14. Apply the flues support bracket „G" to the wall
adherent to the ceiling, use the flues support bracket
as a perforation diagram (if present, the small slot
on the support must coincide with the line drawn
previously on the wall) and mark two holes with a
pencil.
Make the holes (Ø8mm), and insert 2
dowels.
15. Fix the chimney support bracket to the wall using
two 5x45mm screws.
16. Hook the hood onto the bottom bracket.
17. Fix the hood into its final position on the wall
(ABSOLUTELY ESSENTIAL).
18. Connect a pipe (pipe and pipe clamps not provided,
to be purchased separately) for discharge of fumes
to the connection ring located over the suction motor
unit.
If the hood is to be used in ducting version, the other
end of the pipe must be connected to a device
expelling the fumes to the outside. If the hood is to
be used in filter version, then fix the deflector F to
the chimney support bracket G and connect the
other extremity of the pipe to the connection ring
placed on the deflector F.
19. Connect the electricity.
20. Apply the chimney stacks and fasten them at the top
to the chimney support „G" (20b) using 2 screws
(20a)
Only for the model with control panel on the flue:
Only if the control panel is not mounted on the
lower flue:
Insert the small plate of the commands coming
from the motor group into the slot of the flue, from the
interior to the exterior (20c).
Connect the control panel to the small plate.
Attention! The pin of the small plate terminal
MUST correspond to the hole made in the connection
plinth on the back of the control panel.
Only if the control panel is already mounted on
the lower flue:
Connect the control panel to the electronic box of the
hood.
Attention! The pin of the small plate MUST
correspond to the hole made in the connection plinth
on the electronic box (20d).
21. Slide the bottom section of the chimney down until it
completely covers the suction unit and slots into the
housing provided on top of the hood.
22. Fix the lower section of the chimney with two screws.
Remount the carbon filter frame and the fat/s filter/s and
check the perfect functioning of the hood.