Watts OneFlow OF817-8H Manual De Instalación, Operación Y Mantenimiento
Ocultar thumbs Ver también para OneFlow OF817-8H:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Installation, Operation and
Maintenance Manual
Model OF817-8H
OF817-12H
OF1019-20H
OneFlow
Anti-Scale Systems for
©
Hot Water
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
Introduction
The OneFlow
Anti-Scale System for hot water provides pro-
®
tection from scale formation on internal plumbing surfaces
where the hot water feed line is being further heated (booster
heater) or brought to steam (steam generator, autoclave).
The OneFlow
system uses specially designed components
®
to work in applications where the incoming water is heated
between 100°F – 140°F (38 - 60°C) but has not yet been
treated for scale control. These types of applications typically
involve protecting and extending the life of equipment and
instruments from the damaging effects of hard water scale.
OneFlow
prevents scale by transforming dissolved hardness
®
minerals into harmless, inactive microscopic crystal particles.
These crystals stay suspended in the water and are passed
to drain thereby having a greatly reduced ability to react nega-
tively, like dissolved hardness does, particularly in high tem-
perature applications where scale formation is accelerated.
The system requires very little maintenance, no backwashing,
no salt and no electricity. Typical hardness problems, espe-
cially build-up of scale in boilers and steamers are no longer a
concern.
OneFlow
is not a water softener or a chemical additive (like
®
anti-scalants or sequestrants). It is a scale prevention device
with proven third party laboratory test data and years of suc-
cessful Commercial and Medical applications. OneFlow
one water treatment device that effectively provides scale pro-
tection and is a great salt-free alternative to water softening
(ion exchange) or scale sequestering chemicals. Laundry and
warewashing chemistry will likewise require adjustments.
OneFlow
®
• Chemical-free scale prevention and protection – converts hard-
ness minerals to harmless, inactive microscopic crystals making
OneFlow
an effective alternative technology to a water softener
®
for the prevention of scale due to water hardness
• Virtually maintenance free - no control valve
• System and components designed to work specifically with hot
water applications
• Uses environmentally friendly technology by using no salt or
other chemicals to constantly add, no electricity and no waste-
water
• Improves efficiency of all hot water boosting or steam generat-
ing equipment
• Simple sizing and installation – all you need to know is pipe size
and flow rate
• Built-in bypass valve provides flexibility for off-line service or
media replacement
• OneFlow
does not remove minerals or add sodium to the
®
water supply
• Long life media requires replacement once every three years
• Effective retro-fit technology where scale control was not previ-
ously considered.
is the
®
!
WARNING
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
IOM-OF817-8H_12H_1019-20H
Benefits
One Flow media is certified by the Water
Quality Association (WQA) to NSF / ANSI
Standards 42, 61, and 372.

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Watts OneFlow OF817-8H

  • Página 1 IOM-OF817-8H_12H_1019-20H Installation, Operation and Maintenance Manual Model OF817-8H OF817-12H OF1019-20H OneFlow Anti-Scale Systems for © Hot Water WARNING Read this Manual BEFORE using this equipment. OneFlow Benefits ® Failure to read and follow all safety and use information can result in death, serious personal injury, property •...
  • Página 2 (<100F) water. For cold water operation contact your hard scale deposits. A Point of Use (POU) Water Softener should Watts Representative for a system designed for cold water be used on mandatory spot-free applications (e.g. glass stemware, operation.
  • Página 3: Equipment Specifications

    ⁄ ⁄ ⁄ unit into service. For applications with copper concentra- tion greater than 1.3 ppm, please consult Watts Water Quality Technical Service. To further minimize any problem with excess copper, avoid applying excessive flux on the Weight inner surfaces of the pipe and use a low-corrosivity water soluble flux listed under the ASTM B813 standard.
  • Página 4 Stainless Steel OUT - OneFlow ® Treated Water connectors (not suppled with the system but avail- able from Watts). Observe standard plumbing prac- tices and local plumbing O-ring codes. Pour the new Lube the O-ring on the un- 3.
  • Página 5 7. Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made. 8. Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then current production.
  • Página 6: Introducción

    IOM-OF817-8H_12H_1019-20H Manual de instalación, funcionamiento y mantenimiento Sistema antisarro Modelo OF817-8H OF817-12H OF1019-20H OneFlow Sistemas antisarro © para agua caliente ADVE RTE N CIA Lea este manual ANTES de utilizar el equipo. Beneficios de OneFlow ® Si no lee y respeta toda la información sobre seguridad y uso, las consecuencias pueden ser la muerte, lesiones •...
  • Página 7: Especificaciones

    (< 100 °F [38 °C]). Para la operación con agua fría, químicas adicionales. Según la dureza, se pueden producir manchas comuníquese con su representante de Watts para obtener un sistema de sarro suave. En la mayoría de los casos, las manchas de sarro diseñado para la operación con agua fría.
  • Página 8: Especificaciones Del Equipo

    Watts reemplazan la derivación del sistema cada vez que se drene el sistema de tuberías.
  • Página 9: Procedimiento De Reemplazo Del Medio

    SALIDA: agua de acero inoxidable (no tratada con suministrados con el sistema, OneFlow ® pero disponibles en Watts). Observe las prácticas de plomería estándar y los códigos locales de plomería. Junta tórica 3. Coloque la válvula de Vierta el medio Lubrique la junta tórica en...
  • Página 10: Garantía Limitada

    8. Watts Regulator Company se reserva el derecho de realizar cambios o sustituciones en las piezas o el equipo por materiales de valor o calidad equivalente y de producción vigente en ese momento.
  • Página 11: Avantages De Oneflow

    IOM-OF817-8H_12H_1019-20H Manuel d’installation, d’utilisation et d’entretien Système anti-tartre Modèle  OF817-8H OF817-12H OF1019-20H Systèmes anti-tartre OneFlow ® pour eau chaude AVERT IS SE ME N T Lisez ce manuel AVANT d’utiliser cet équipement. Le non-respect de toutes les instructions de sécurité et Avantages de OneFlow ®...
  • Página 12: Caractéristiques Techniques

    (< 100°F [38°C]). Pour un fonctionnement avec eau l’eau potable en un seul passage SANS additifs chimiques supplémentaires. froide, communiquez avec votre représentant Watts pour un système Selon la dureté, de légères traces de tartre pourraient apparaître. Ces légères conçu pour l’eau froide.
  • Página 13: Spécifications Mécaniques

    1,3 ppm, veuillez communiquer avec l’équipe d’assistance technique de Poids Watts Water. Pour réduire davantage tout problème d’excès de cuivre, évitez d’appliquer un débit trop élevé sur les surfaces intérieures des tuyaux et utilisez un flux soluble à l’eau peu corrosif conforme à...
  • Página 14 SORTIE – Eau traitée acier inoxydable (non fournis avec le système, mais offerts OneFlow ® chez Watts). Respectez les pratiques standards et les codes locaux de plomberie. Joint torique 3. Placez la vanne de dérivation en position SERVICE (illustré...
  • Página 15: Garantie Limitée

    GARANTIE TACITE DE QUALITÉ MARCHANDE OU D’ADAPTATION À UN BUT PARTICULIER. Le recours décrit en vertu de cette garantie constitue le seul recours à toute violation de la présente garantie et Watts Regulator Company ne saurait être tenue responsable de tout dommage accessoire, spécial ou indirect, y compris, sans s’y limiter : le transport, la manutention, la perte de profits ou le coût afférent à...

Este manual también es adecuado para:

Oneflow of817-12hOneflow of1019-20h

Tabla de contenido