7) MALFUNCTIONS
No chlorine is being produced in the pool:
Check to make sure that:
The unit is connected;
The fuse is not damaged or blown;
The ON/OFF switch is in position I;
The chlorine control is not set too low;
The cell is clean;
The pump motor is working;
The safety wire is connected and not damaged;
Indicators LED 1 and LED 2 are both showing green. If either or both are red, see
Section 5 "OPERATION" above.
During the season, the "WINTER MODE" selector should be in the OFF position.
There is insufficient chlorine:
Check to make sure that:
The cell is clean;
The filter is clean;
You have the right amount of stabiliser;
The pH value is correct (around 7.2);
The salt content is right:
- Pro-MATIC - ESC models – minimum 3 g/ litre;
- Eco-MATIC - ESR models - minimum 4 g / litre;
The chlorine control setting is right: turn the knob clockwise to increase
production.
During the season, the "WINTER MODE" button should be in the OFF position.