Be sure to note proper
polarity of batteries
Notes:
Use alkaline batteries only. Do not use rechargeable batteries.
When replacing batteries, always replace both batteries with new batteries, do not mix old and new batteries.
If the air conditioner will not be used for an extended period of time, remove the batteries from the remote
control.
4. Remote Control Storage
1) Insert remot e controller into the bracket in back of unit,
2) In order to avoid losing the remote control, please keep it stored when you do not use it.
Important:
The compressor will start approximately 3 minutes aft er the unit is turned on (this will help prolong the life of
the compressor). A fter switching the unit off, please wait at least 3 minutes before turning the unit back on.
The compressor will switch off when the room temperature is lower than the set temperature. The fan will
however, continue to work. When the ambient temperature rises above the set temperature, the cooling will
resume.
ATTENTION: This portable air conditioner has a number of key safety protection feat ures:
1. Anti-frozen protection function
Under COOL mode, when the compressor continuously runs over 10 minutes, if tube temperature is ≦2℃/36℉
for 20 seconds, the anti-frozen protection function will be on, E4 will be shown on LCD display, compressor and
water wheel motor will stop working, but upper fan remains running; If tube temperature is ≧8℃/ 46℉, the unit will
stop anti-froz en protection and recover to original working condition. Compressor will re-start with 3 minutes delay
for protection.
2. Auto Defrosting Operation
When the coil temperat ure is too low and the humidity is too high, frost may form on the coils. The air conditioner
will then stop operation for 8-10 minutes for an auto defrosting to take place, until the coils have achieved a
9