EN
CLEANING AND MAINTENANCE
Replacing the cartridge
1. Shut off the water supply to the
faucet.
2. Turn on the faucet briefly to relieve
any pressure inside the faucet.
3. Move the faucet handle to the "OFF"
position.
4. Remove the set screw from the
handle assembly (A) using a 2.5 mm
hex key.
5. Pull the lever handle (A) and cartridge
cap (B) from the faucet body.
6. Unscrew the cartridge lock nut (C).
7. Lift ceramic disc cartridge (D) from
the body and repalce it with a new one.
Ensure the two lugs on bottom of the
cartridge sit properly in the allocated
holes at the base of the body.
8. Re-assemble faucet in reverse order.
9. Test for leakage.
3A
General maintenance
Clean aerator periodically for any
buildup (fig. 2D and 2E).
Do not use harsh detergents, solvents,
chemical agents, especially CHLORINE
or metallic sponges as these can
damage the surface finish. Clean only
with a soft sponge and soapy water.
Do not store chemicals or cleaning
agents in the immediate vicinity of the
faucet and connection hoses. Chemical
vapors could cause damage.
D
C
30 mm
106 in-lbs
– 6 –
B
A
2,5 mm