11.12 Large flush volume
Flush volume OK:
11.13 Wait 20 seconds outside of the sensor range (the fitting switches automatically to the
normal operating mode).
11.14 Attach the cover plate (see
Flush volume NOT OK:
11.15 Hold your hand a distance of 5 - 10 cm in front of the sensor. The LED flashes.
2 flashes, pause, 3 flashes, pause, 4 flashes, etc.

12. Adjusting the flushing flow

12.1 Remove the cover plate (see
12.2 Adjusting the flushing flow
+ increase flushing flow
– decrease flushing flow
12.3 Attach the cover plate (see

13. Setting the range

13.1 The sensor range can be adjusted using the optional remote control
(Order No. 5179 0000).

14. Maintenance

Changing the solenoid valve cartridge
14.1 Remove the cover plate (see
14.2 Close the flow volume regulator (see
Screw flow volume regulator up to the stop limit.
!
Caution!
Do not remove the retaining ring.
14.3 Disconnect the control unit from the solenoid valve cartridge.
14.4 Unscrew the solenoid valve cartridge using the assembly key (flushing plugs).
14.5 Reassemble in the reverse order.
Important!
Carefully tighten the solenoid valve cartridge.
!
Caution!
Keep the flushing plugs in the flush-mounting cabinet to enable removal of the solenoid
valve cartridge at a later date.
chapter
9.17).
chapter
11.1).
chapter
9.17).
chapter
11.1).
chapter
9.3).