Setup
Hydraulic Connection
1. Clean all couplers, threaded fittings, ports, and the
area around all ports.
2. Remove any dust plugs from the couplers.
3. Hand-tighten all couplers firmly (until all threads are
fully engaged). Do not use tools.
Greenlee / A Textron Company
976-22 and 980-22 Hydraulic Power Pumps
Grounding Instructions
This tool must be grounded. In the event of a malfunc-
tion or breakdown, an electrical ground provides a path
of least resistance for the electric current. This path of
least resistance is intended to reduce the risk of electric
shock.
This toolʼs electric cord has a grounding conductor and
a grounding plug as shown. Do not modify the plug.
Connect the plug to a corresponding 15 A GFCI-
protected receptacle that is properly installed and
grounded in accordance with all national and local codes
and ordinances.
Do not use an adapter.
Extension Cord Specifications
Cord Diameter (minimum)
976-22 ............................................ 1.5 mm
980-22 ............................................ 2.5 mm
Cord Length (maximum) ...............................30 m (100 ft)
Use only three-wire extension cords. Use of an
inadequate extension cord will cause the motor to stall.
6
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
Electric shock hazard:
• Do not modify the plug provided
with the tool.
• Connect this tool to a grounded re-
ceptacle on a 15 A GFCI-protected
circuit.
Failure to observe these warnings
could result in severe injury or death.
����
����������
(14 AWG)
2
(12 AWG)
2