Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the
air compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Motor Overload
Protector (not
shown): The motor has an automatic
reset thermal overload protector, if
the motor overheats for any reason,
the overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting.
The
compressor will automatically
restart
after the motor cools.
HOW TO USE YOUR UNiT
How to Stop
1.
Set the On/Off switch to "Off".
Before
Starting
_Do
not operate this
unit until you read
and understand
this instruction
manual for safety, operation
and
maintenance
instructions.
3.
Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
4.
Move the On/Off switch to "On"
position. The compressor will start.
5.
Run the compressor
for 15 min-
utes. Make sure the drain valve
is open and there is minimal air
pressure build-up in tank.
6.
After 15 minutes, close the drain
valve by turning clockwise. The
air receiver will fill to "cut-out"
pressure and the motor will stop.
The compressor is now ready for use.
Before
Each Start-Up
1.
Set the On/Off switch to "Off".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Attach hose and accessories.
_Risk
of unsafe
operation.
Firmly
grasp air hose in hand when
installing or disconnecting
to
prevent hose whip.
_Risk
of unsafe
operation.
Do not
use
damaged
or worn accessories.
NOTE: The hose or accessory will
require a quick connect plug if the air
outlet is equipped with a quick con-
nect socket.
Break-in
Procedure
_Risk
of Unsafe
Operation. Serious
damage may result if the following
break-in
instructions are not closely
followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1.
Make sure the On/Off switch is in
the "Off" position.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to "Voltage and Circuit
Protection"
paragraph in
the Installation section of
this manual.)
_Risk
of Bursting.
Too much air
pressure causes a hazardous risk of
bursting.
Check the manufacturer's
maximum
pressure rating for air
tools and accessories.
The regulator
outlet pressure
must never exceed
the maximum
pressure rating.
_Risk
of unsafe
operation.
Compressed
air from the unit may
contain water condensation
and
oil mist. Do not spray unfiltered
air
at an item that could be damaged
by moisture. Some air tools and
accessories
may require filtered
air. Read the instructions for the air
tools and accessories.
13-ENG