4.3
Mounting
attENtioN
Do not expose any component of ControlGo to
vibrations or heat radiation.
You must install the Panel at a clearly visible and accessible
position.
4.3.1
ControlGo/Panel
To install the Panel, do the following.
Fig. 4.2
•
Attach the mounting brackets (A) to the Panel with the
supplied mounting material (B).
•
Install the Panel to the wall. Make sure that it is level.
attENtioN
Before you install the Panel, make sure that the wall
is strong enough. Refer to paragraph 1.5.1 for the
weight.
Fig. 4.2
Mounting of the Panel
Fig. 4.3
North America only:
•
To comply with UL standard 508A, put the corresponding
sticker on the Panel.
WARNING
Maintenance on Industrial Control
Panels shall only be performed by
trained,
qualified,
skilled
and
authorized
electricians,
using
appropriate
safe
electrical
work
practices including personal protective
equipment, approved tools, procedures
and accurate drawings of the panels
involved.
CAUTION
Risk of Electric shock
Disconnect Switch may be required to
de-energize before servicing.
AVERTISSEMENT
L'entretien des armoires industrielles
de
contrôle
doit
être
effectué
uniquement
par
des
personnes
qualifiées, expertes et autorisés en ce
sens utilisant des méthodes de travail
appropriées et sécurisées, y compris
les
équipements
de
protection
individuelle, les outils, les procédures
approuvées et schémas électrique des
armoires en question.
ATTENTION
Risque de tension électrique
Il pourrait être nécessaire d'installer
un interrupteur principal pour mettre
hors-tension
la
machine
avant
d'entreprendre les travaux d'entretien.
Fig. 4.3
UL compliance sticker
The bottom plate contains the following cable glands and
connectors:
Fig. 4.4
A
metal cable gland M20 for the mains cord
B
universal cable glands M16 (6)
C
bulkhead connectors (2) for the pressure tubes
12. Filter pressure + and –
0000112607/170717/0 ControlGo
B (4x)
A (4x)
12
A
Fig. 4.4
Bottom plate
Table I on page 77 gives an overview of the necessary and
optional cables that you need to install the system.
•
Depending on the selected options and control equipment,
determine the number and type of cables that you need.
If the number exceeds 6 cables (excluding the mains cord),
you must install additional cable glands. In that case, do the
following.
Fig. 4.5
•
Loosen the pneumatic hoses (B) from the bulkhead
connectors from the inside of the Panel.
•
Loosen and remove the bottom plate (C+D).
•
Open the necessary number of knock-out holes
•
Put additional cable glands M16 (E) in the bottom plate and
tighten them.
•
Install the bottom plate.
•
Fasten the pneumatic hoses to the bulkhead connectors.
WaRNiNG
You must remove the bottom plate to put additional
cable glands to avoid damage to the interior parts of
the Panel.
A
A
A
D
D
D
Fig. 4.5 Additional cable glands (optional)
4.4
Electric connection
This chapter describes the electric connection of all necessary
and optional components to the Panel.
13. Max. 12
B
C
(A).
13
B (2x)
B (2x)
C (6x)
C (6x)
B (2x)
C (6x)
E
E
E
B
C
B
C
B
C
EN - 6