TROUBLESHOOTING
Problem
Cause / Solution
Light Does Not
No power to the fixture.
Come On
• Check if circuit breaker tripped.
• Confirm wall switch is ON.
Bulb is not screwed in properly.
• Refer to "Installing the Bulb" instructions.
Self-diagnostic red LED indicator light is on.
• Replace bulb.
• If light still does not come on after replacing bulb, contact
Customer Service.
Fixture is sensing daylight.
• Cover photo control. Unit will switch ON immediately.
Wiring to the unit is loose.
• Confirm wiring is properly secured.
Caution: Turn off power before checking.
Light Cycles
Light sensor is sensing reflected light.
On and Off
• Apply photo control cover.
Continuously
• Relocate light fixture where it no longer cycles on and off.
Light Stays On
Light sensor is in a shaded area.
• Shine a flashlight into the light sensor. If the light turns off, the
fixture is mounted in an area that does not allow enough light
to enter the light sensor.
Light sensor is faulty.
• Self-diagnostic red LED light will automatically turn on if the
fixture is no longer operating correctly or if bulb needs to
be replaced.
2-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting, LLC ("Cooper Lighting") warrants to customers that, for a period of two years
from the date of purchase, Cooper Lighting's products will be free from defects in materials
and workmanship. The obligation of Cooper Lighting under this warranty is expressly limited
to the provision of replacement products. This warranty is extended only to the original
purchaser of the product. A purchaser's receipt or other proof of date of original purchase
acceptable to Cooper Lighting. This is required before warranty performance shall be rendered.
This warranty does not apply to Cooper Lighting products that have been altered or repaired or
that have been subjected to neglect, abuse, misuse or accident (including shipping damages).
This warranty does not apply to products not manufactured by Cooper Lighting which have
been supplied, installed, and/or used in conjunction with Cooper Lighting products. Damage to
the product caused by replacement bulbs or corrosion or discoloration of brass components
are not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL,
OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN
CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS;
NOR SHALL THE LIABILITY OF COOPER LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING
OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE,
MAINTENANCE, REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS, OR SUPPLY OF
ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING
PRODUCTS GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR
INSTALL FIXTURES.
To obtain warranty service, please contact Cooper Lighting, LLC, at 1-800-334-6871, press
option 2 for Customer Service, or via e-mail ConsumerProducts@cooperlighting.com and
include the following information:
• Name, address and telephone number
• Date and place of purchase
• Catalog and quantity purchase
• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number issued
by the Company and must be returned freight prepaid. Any product received without a Return
Goods Authorization Number from the Company will be refused.
Cooper Lighting, LLC is not responsible for merchandise damaged in transit. Repaired or
replaced products shall be subject to the terms of this warranty and are inspected when
packed. Evident or concealed damage that is made in transit should be reported at once to
the carrier making the delivery and a claim filed with them.
Reproductions of this document without prior written approval of Cooper Lighting, LLC are strictly prohibited.
For assistance, call 1-800-334-6871 or e-mail us at ConsumerProducts@cooperlighting.com.
Printed in China
ESPAÑOL
ARTÍCULOS NECESARIOS
(se compran por separado)
• Destornillador en cruz (Phillips)
• Limpiar masilla de silicona resistente a la intemperie
ADVERTENCIAS Y PRECAUCIONES
• Se debe utilizar en exteriores solamente.
• Catalogado por cULus para uso en ubicaciones húmedas.
• Portalámparas diseñado para montaje en pared a una caja de conexiones solamente.
Instale el portalámparas en la caja de conexiones que se encuentra marcada para uso en
lugares húmedos.
• Conecte el accesorio a una fuente de energía de 120 voltios y 60 Hz. Cualquier otro tipo de
conexión anulará la garantía.
• El portalámparas debe ser instalado por personas con experiencia en cableado doméstico
o por un electricista calificado. El sistema eléctricoy el método de conexión eléctrica
del portalámparas debe cumplir con el Código eléctrico nacional y los códigos locales
sobre edificios.
• Reemplace la bombilla por una de 26 vatios o menos. Si instala lámparas de mayor
potencia, puede crear riesgo de incendio y se anulará la garantía.
• La lámpara es precableada y ensamblado para facilitar la instalación.
Aviso: Las bombillas contienen mercurio y se deben desechar de acuerdo a las leyes
federales, estatales o locales. Para más información, visite: www.lamprecycle.org.
PARA OBTENER LOS MEJORES RESULTADOS
• Instale la luz de patio a 2,13– 3,04 m (7 –10 pies)
sobre el suelo.
• No monte el portalámparas cerca de superficies
reflectantes tales como ventanas, paredes blancas,
superficies blancas y agua.
• Cuando instale dos portalámparas en un único
interruptor, asegúrese de que el interruptor esté
clasificado para, por lo menos, una carga
inductiva 1 A.
MONTAJE DEL PORTALáMPARAS
NOTA: No monte dentro de los 0,61 m (2 pies) que
conforman una esquina interna que es altamente
reflectante desde el exterior (Fig. 1).
1. Desconecte la alimentación en la caja principal de
fusibles/ interruptor de circuito.
2. Desatornille la lente y quite la bombilla (B). Ponga la
lente y la bombilla a un lado.
3. Ajuste el soporte para montaje (C) a la caja de
conexiones con los dos tornillos (D) provistos (Fig. 2).
4. Atornille la varilla roscada para montaje (E) dentro
del centro del soporte para montaje (C) hasta que
los hilos se muestren en la parte trasera del soporte
para montaje (C) (Fig. 3).
5. Quite el papel protector de la junta (F) y ajuste la
junta (F) al portalámparas (Fig. 4).
NOTA: Alinee los semicírculos de la junta (F) con los
tornillos en la parte trasera del portalámparas y, luego,
presione firmemente.
CABLEADO DEL ACCESORIO
1. Desconecte la alimentación en la caja principal de
fusibles/ interruptor de circuito.
2. Conecte el cable negro del portalámparas al
cable negro de suministro (activo) a través del
cable conector (G) (Fig. 5).
3. Conecte el cable blanco del portalámparas al
cable blanco de suministro (neutral) a través del
cable conector (G) (Fig. 5).
4. Conecte el cable cobre de toma a tierra del
portalámparas a una conexión a tierra de suministro
apropiada o a una caja de conexiones conectada
a tierra.
NOTA: Conecte los cables correctamente. Asegúrese
de que no haya cables ni alambres sueltos que se
extiendan sobre el cable conector (G) provisto o sobre
otros cables conectores aprobados (no provistos).
5. Ajuste el portalámparas a la varilla roscada para
montaje (E).
6. Asegúrelo con la tuerca tapa (H) (Fig. 6).
2
Fig. 1
2 pies
2 pies
2 pies
Fig. 2
Caja de
conexiones
D
D
C
Fig. 3
Caja de
conexiones
E
C
Fig. 4
A
F
Papel protector
Fig. 5
Caja de conexiones
E
G
G
Fig. 6
Caja de conexiones
E
H

Publicidad