Ribind RAPID N Manual De Instrucciones página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
TABLE FOR THE ADJUSTMENT OF SPRINGS FOR A 3 m - LONG BOOM
BOOM TYPE
Ø 80 RIB Boom
Ø 80 RIB Articulated boom
Ø 80 RIB Boom and hanging support
Ø 80 RIB Boom and fotocosta unit
Ø 80 RIB Boom and fotocosta unit + hanging support
Ø 80 RIB Boom and hanging rack
Ø 80 RIB Boom and hanging rack + magnet
Ø 80 RIB Boom and hanging rack + hanging support
Ø 80 RIB Boom and fotocosta unit + magnet
Ø 80 RIB Boom and magnet
TABLE FOR THE ADJUSTMENT OF THE SPRINGS FOR A 4 m - LONG BOOM
BOOM TYPE
Ø 80 RIB Boom
Ø 80 RIB Articulated boom
Ø 80 RIB Boom and hanging support
Ø 80 RIB Boom and fotocosta unit
Ø 80 RIB Boom and magnet
Ø 80 RIB Boom and fotocosta unit + hanging support
Ø 80 RIB Boom and fotocosta unit + magnet
Ø 80 RIB Boom and hanging rack
Ø 80 RIB Boom and hanging rack + magnet
Ø 80 RIB Boom and hanging rack + hanging support
TABLE FOR THE ADJUSTMENT OF THE SPRINGS FOR A 5 m - LONG BOOM
BOOM TYPE
Ø 80 RIB Boom
Ø 80 RIB Articulated boom
Ø 80 RIB Boom and hanging support
Ø 80 RIB Boom and fotocosta unit
Ø 80 RIB Boom and magnet
Ø 80 RIB Boom and hanging rack
Ø 80 RIB Boom and hanging rack + magnet
Ø 80 RIB Boom and hanging rack + hanging support
Ø 80 RIB Boom and fotocosta unit + hanging support
Ø 80 RIB Boom and fotocosta unit + magnet
TABLE FOR THE ADJUSTMENT OF THE SPRINGS FOR A 6 m - LONG BOOM
BOOM TYPE
Ø 80 RIB Boom
FITTING 2 BALANCING SPRINGS
Remove the control board plastic box in a way to create space within the column.
Pic. 1 - Initial view of the springless balancing-unit with a Nylon tie for transport.
Pic. 2 - Loosen and remove the bottom screw securing the aluminium section of the limit-switch-group.
Pic. 3 - Remove the bottom black plastic cap from the limit-switch-group.
Pic. 4 - Unscrew the two ring nuts from the balancing-unit
Pic. 5 - Remove the lower balancing-unit piece.
Pic. 6 - Remove the two plastic washers from the central pipe, they are useless to install just two balancing
springs.
Pic. 7 - Fit the two springs on the side pipes. N.B. Springs must be chosen following the SPRINGS
CHOICE AND ADJUSTMENT TABLE.
Pic. 8 - Fit the lower balancing-unit in a way that its two plastic elements touch the side springs.
Pic. 9 - Screw the first ring nut in a way that its side with the larger smooth surface touches lower
balancing-unit.
N.B.: SCREW THE RING NUT AS SHOWN IN THE TABLE ABOVE (TENSION H - Picture
4 Page 28).
Screw the second ring nut in away to block the first one.
Pic. 10 - Fasten tight.
Pic. 11 - Fit the bottom black plastic cap to the the limit-switch-group.
Pic. 12 - Fit the bottom screw securing the aluminium section of the limit-switch-group.
Pic. 13 - Fasten tight.
Pic. 14 - Cut the top Nylon tie securing the balancing unit for transport.
Go ahead to assemble the arm following the indications provided in the "ARM ASSEMBLY" paragraph.
CODE
ACG8501+ACG8548
ACG8223+ACG8548
ACG8501+ACG8548+ACG8283
ACG8501+ACG8548+ACG7090+ACG8610
ACG8501+ACG8548+ACG7090+ACG8610+ACG8283
ACG8501+ACG8548+ACG8291
ACG8501+ACG8548+ACG8291+ACG8073
ACG8501+ACG8548+ACG8291+ACG8283
ACG8501+ACG8548+ACG7090+ACG8610+ACG8073
ACG8501+ACG8548+ACG8073
CODE
ACG8502+ACG8548
ACG8224+ACG8548
ACG8502+ACG8548+ACG8283
ACG8502+ACG8548+ACG7090+ACG8610
ACG8502+ACG8548+ACG8073
ACG8502+ACG8548+ACG7090+ACG8610+ACG8283
ACG8502+ACG8548+ACG7090+ACG8610+ACG8073
ACG8502+ACG8548+ACG8290+ACG8290
ACG8502+ACG8548+ACG8290+ACG8290+ACG8073
ACG8502+ACG8548+ACG8290+ACG8290+ACG8283
CODE
ACG8503+ACG8548
ACG8225+ACG8548
ACG8503+ACG8548+ACG8283
ACG8503+ACG8548+ACG7090+ACG8610
ACG8503+ACG8548+ACG8073
ACG8503+ACG8548+ACG8290+ACG8291
ACG8503+ACG8548+ACG8290+ACG8291+ACG8073
ACG8503+ACG8548+ACG8290+ACG8291+ACG8283
ACG8503+ACG8548+ACG7090+ACG8610+ACG8283
ACG8503+ACG8548+ACG7090+ACG8610+ACG8073
CODE
ACG8506+ACG8548
*(see pic. 4 - page 28) ** It may vary according to where the articulated boom arm is divided
26
26
SPRINGS TO ORDER
n. 3 ACG8640 Ø 4
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5
SPRINGS TO ORDER
n. 1 ACG8640 Ø 4 + n. 2 ACG8641 Ø 4,5 20
n. 3 ACG8641 Ø 4,5
n. 3 ACG8641 Ø 4,5
n. 3 ACG8641 Ø 4,5
n. 3 ACG8641 Ø 4,5
n. 2 ACG8641 Ø 4,5 + n. 1 ACG8642 Ø 5 20
n. 2 ACG8641 Ø 4,5 + n. 1 ACG8642 Ø 5 25
n. 3 ACG8641 Ø 4,5
n. 2 ACG8642 Ø 5 + n. 1 ACG8641 Ø 4,5 20
n. 1 ACG8641 Ø 4,5 + n. 2 ACG8642 Ø 5 20
SPRINGS TO ORDER
n. 2 ACG8642 Ø 5 + n. 1 ACG8641 Ø 4,5 20
n. 2 ACG8642 Ø 5 + n. 1 ACG8643 Ø 5,5 --**
n. 2 ACG8642 Ø 5 + n. 1 ACG8643 Ø 5,5 15
n. 2 ACG8642 Ø 5 + n. 1 ACG8643 Ø 5,5 15
n. 2 ACG8642 Ø 5 + n. 1 ACG8643 Ø 5,5 15
n. 2 ACG8643 Ø 5,5 + n. 1 ACG8642 Ø 5 15
n. 3 ACG8643 Ø 5,5
n. 3 ACG8643 Ø 5,5
n. 3 ACG8643 Ø 5,5
n. 3 ACG8643 Ø 5,5
SPRINGS TO ORDER
n. 3 ACG8643 Ø 5,5
1
3
TENSION H*
20
--**
20
20
25
20
25
25
25
20
TENSION H*
--**
20
20
20
20
TENSION H*
20
20
20
15
TENSION H*
15
2
4

Publicidad

Tabla de contenido
loading

Productos relacionados para Ribind RAPID N

Este manual también es adecuado para:

Rapid n metal

Tabla de contenido