• Inserting a code with more than 6 digits will cancel the operation in progress.
Signal: the keyboard will sound a beep and the red LED lights up.
• The available time between inserting one digit and the next is 5 seconds. Once the time has expired the
operation will be cancelled.
• Once the code has been memorised by either pressing # or waiting for 20 seconds you will be moved out
of the procedure.
Signal: the red LED will flash on the keyboard followed by 6 sequential beeps.
• Before memorising codes for the first time, change the password ("123456") and cancel the entire memory
content.
Cancelling the entire memory content does not cancel the password
• After inserting a wrong code (not present in memory) three times the system will remain blocked for twenty
seconds.
Signal: the keyboard sounds 3 beeps and the red and green LEDs flash.
• If the batteries are not well charged you may consider replacing them.
Signal: pressing any key in the function mode will light the green and red LEDs.
Error signals
Red LED flashing
- in the memorisation mode accompanied by three slow beeps, the code is already memorised
- in the cancel mode: the code doesn't exist.
- in the function mode accompanied by three rapid beeps, the code is wrong.
NOTES