A
- CONNECTIONS
J1
L-N
230VAC 50/60HZ POWER SUPPLY
(120VAC/60HZ UPON REQUEST)
J2
COURTESY LIGHT OR BLINKER (MAX 40W )
U
MOTOR COMMON CONNECTION
V-W
MOTOR PHASES AND CAPACITOR
CONNECTIONS
J3
AERIAL
RADIO ANTENNA
A+A-
POWER SUPPLY FOR ACCESSORIES 24VDC
COM.
CONTACTS COMMON UNIT
K BUTT.
CONTACT OF A SINGLE IMPULSE (NO)
PHOTO
PHOTOCELLS CONTACT (NC)
EDGE
SAFETY STRIP CONTACT IN OPENING AND
CLOSING (NC)
A+ TEST
ACCESSORIES POWER SUPPLY +24VDC
FUSES
F1 => T100mA
F2 => T5A
RELAYS AND MOTOR CONTROL
K1 =>
Flasher control
K2 =>
Opening travel control
K3 =>
Closing travel control
Q4 =>
TRIAC Motor control, open and close
B
- SETTINGS
OPERATION MICROSWITCHES
DIP 1 ON - CHECKING THE ROTATION DIRECTION OF THE MOTOR
(POINT C)
DIP 1 ON - ENABLING OF MANNED POSITION SETTING (POINT D)
DIP 2 ON - TIMING (POINT E)
DIP 1-2 DIP1 ON FOLLOWED BY DIP2 ON
READ IN/CANCELLATION RADIO CODES FOR MOTOR
CONTROL ONLY FOR CRX MODELS (POINT F)
OPERATING MICROSWITCH
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - For external flasher
OFF - For internal courtesy light
DIP 6
ON - STEP BY STEP
Single pulse contact (K BUTT)
OFF - AUTOMATIC
Single pulse contact (K BUTT)
DIP 7
ON - Safety strip self test ENABLED
OFF - Safety strip self test DISABLED
DIP 8
ON - Blinker pre-flashing
OFF - Blinker normal flashing
TORQUE - ELECTRONIC TORQUE REGULATOR
The torque is regulated by rotating the Trimmer TORQUE, varying the
output voltage of motor ends,(when rotated clockwise, more torque Is
transmitted to the motor).
Such torque is automatically included 3 seconds after the start of every
J4
SW J AND
D O N O T T O U C H T H E J U M P E R ! I F I T I S
RADIO
REMOVED THE OPERATOR DOESN'T MOVE !
J5
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER
24VDC (NOT CRX MODELS)
J6
RADIO
IN BUILT RADIO MODULE (MODELS CRX)
TR1
TORQUE
ELECTRONIC TORQUE REGULATOR
S1
PROG.
PUSH-BUTTON FOR THE PROGRAMMING
operating cycle.
This allows the motor to have the maximum pickup when it starts.
NOTE: IN CASE THE ABOVE TRIMMER IS SET FOLLOWING THE
PROGRAMMING PROCEDURE, THE SLOWING STROKE
STARTING POINT CAN CHANGE (ANTICIPATING OR DELAYING
THE SET VALUE), THEREFORE UPON A NEW TRIMMER
SETTING, A NEW TIME ADJUSTMENT IS RECOMMENDED.
LED SIGNALS
DL1 - (Red)
- Programming operated
DL2 - (Green) - Radio programming activated (models CRX only)
DL3 - (Red)
- Safety strip contact (NC)
DL4 - (Red)
- Photocell contact (NC)
DL5 - (Red)
- K BUTT command light
DL6 - (Red)
- Shutter is closing
DL7 - (Green) - Shutter is opening
C
- CHECKING THE ROTATION DIRECTION OF THE MOTOR
This control is carried out to facilitate the installation of the system or any
possible future control.
WITH FENCE LOWERED AND LOWER STROKE END SWITCH
CORRECTLY SET.
1 - Put DIP1 in the ON mode => The LED DL1 starts blinking;
CAUTION: in case the pushbutton PROG is not operated within
1 min, the LED turns off, the system maintains the
present configuration, see para. "D-MANNED POSITION
SETTING".
2 - Depress and maintain the pushbutton PROG (motion is performed
in manned position setting, open-stop-close-stop-open-etc.) the fence
will open (DL7 green lit).
a - In case the fence closes instead of opening (DL6 RED LIT) release
immediately the pushbutton PROG and set the close stroke end
switch.
b - In case the fence closes instead of opening (DL7 GREEN LIT)
exchange the connection of motor wires V and W on the electrical
unit, or connection blocks 5 and 6 on the stroke end unit JOLLY.
3 - Set the opening stroke end switch. Ensure the end stroke system
stops the motor on completion of opening stroke.
4 - After 3 sec of opening or close travel, the electronic torque increase
gets in operation. Set the electronic torque through the trimmer
TORQUE.
5 - On completion of checks and setting of trimmer, set the DIP1 on OFF.
The LED DL1 turns off (in case still lit) to indicate the end of control
phase.
N.B.: While performing this check, photcells and safety strips are
overridden.