DECORATIVE DUCT COVERS
A decorative duct cover is available to fit both
model widths. The duct cover conceals the
ductwork running from the top of the hood to the
ceiling or soffit. The duct cover will fit 8 ft. to 10 ft.
ceiling heights. See page 13 for details.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V,
60Hz, and connected to an individual, properly
grounded branch circuit, and protected by a 15 or
20 amp circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible in the ceiling or wall.
• Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.
49-2000061 Rev. 1
Installation Preparation
This Hood Must Use 7" Round Duct.
It Can Transition To 3-1/4" x 12" Duct.
Do NOT use flexible plastic ducting.
NOTE: Any home ventilation system, such as
a ventilation hood, may interrupt the proper
flow of combustion air and exhaust required by
fireplaces, gas furnaces, gas water heaters and
other naturally vented systems. To minimize
the chance of interruption of such naturally
vented systems, follow the heating equipment
manufacturer's guidelines and safety standards
such as those published by NFPA and ASHRAE.
When applicable, install any makeup (replacement)
air system in accordance with local building code
requirements. Visit cafeappliances.com for
available makeup air solutions.
Using a smaller diameter duct size
will reduce performance.