KNOWYOUROEHERATOR
I!__-!i] Read the Operator'sManual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Savethis manual for future reference.
Fuel T ank
120 Volt AC, 20 Amp
Duplex Receptacles
Spark Arrester Muffler
120/240 Volt AC,
30 Amp Receptacle
CircuitBreakers (AC)
DoublePoleCircuit
Breaker ( AC)
StatStation
TM
Grounding
Fastener
Data Tag
Air Cleaner
Choke
120 VoltAC, 20 Amp, Duplex Receptacles -- May be used to
supply electricalpowerfor the operationof 120 Volt AC,
20 Amp, single phase,60 Hz electrical,lighting, appliance,tool
and motor loads.
120/240 VoltAC, 30 AmpLockingReceptacle -- May be used
to supply electrical powerfor the operationof 120 and/or
240 Volt AC, 30 Amp, single phase,60 Hz electrical,lighting,
appliance,tool and motor loads.
Air Cleaner-- Protectsengine by filtering dust and debrisout
of intakeair.
Battery FloatChargerJack-- Use batteryfloat chargerto keep
the starting batterychargedand readyfor use.
Choke Lever-- Usedwhen starting a cold engine.
CircuitBreakers (AC)-- Pushto reset circuit breakersare
providedto protectthe 120 VAC,20A duplexreceptaclesagainst
electricaloverload.
DataTag -- Providesmodel, revision and serial numberof
generator.Pleasehavethese readilyavailablewhen calling for
assistance.
EngineRocker
Switch
Recoil Starter
Oil Fill Cap
Lever
Battery Float
Start Switch
Charger Jack
DoublePole CircuitBreaker(AC)-- A double pole circuit
breakeris providedto protectall the receptacles and generator
against electricaloverload.
EngineRockerSwitch -- Setthis switch to "On"beforestarting
engine.Set switch to "Off"to stop engine.
Fuel Tank -- Capacityof seven (7) U.S.gallons.
GroundingFastener - - Consultyour localagency having
jurisdiction for grounding requirementsin your area.
Oil Fill Cap-- Checkand fill engine with oil here.See page17
for oil recommendations and filling instructions.
Recoil Starter -- Usedto start the engine.
SparkArrester Muffler -- Exhaustmuffler lowers engine noise
and is equippedwith a spark arrester screen.
StartSwitch -- Pushand hold in "Start" position for a
maximum of 15 secondsduring each start attempt, until engine
starts.
StatStation
TM
-- Displaysthe nominal load on generatorbased
on output frequency. It also has a built in maintenancereminder.