The HEPA filter is removed by opening the cover and detaching the cartridge. By gently tilting the detached motor head away
from the cyclone, a lateral pressure occurs on the HEPA filter cartridge that is attached to the motor. If necessary, repeat the
procedure until the HEPA filter falls into the fine filter cartridge. The HEPA filter and the fine filter can then be discarded. The new
filter cartridge is placed in the fine filter and is sealed when you carefully fit the cover.
The vacuum unit has an extremely long service life and requires no maintenance. The seals must be checked after approximately
1,000 hours of operation. These parts must be replaced if wear is detected.

Consumables

Description
HEPA filter
Fine filter
Inlet plug
Plastic bag
Air filter for motor cooling
For spare parts, see the
Dustcontrol

Warranty

The warranty period is two years and covers manufacturing defects. The warranty is valid on condition that the machine is used in
the normal way and receives the required service. Normal wear and tear is not covered. Repairs must be carried out by
Dustcontrol or personnnel authorized by Dustcontrol. Otherwise, the warranty is void.

Troubleshooting

Problem
Motor not running.
Motor stops immediately after
starting.
Motor runs, but no suction.
18
2
Part No.
42027H
42028H
42250H
42285H
432183H
website.
Cause
Power supply not connected.
Incorrect fuse.
Suction hose not connected. Hose blocked.
DC 1800H/DC 2800H, Art.nr. 9497-G
3
Action
Connect power supply.
Replace with correct fuse.
Connect hose. Reverse or clean hose.