Menu Option 2: Output to Current Program
1. Select this option to open the currently selected program in memory.
2. Use the arrow keys to move the cursor to the desired insertion point for the new code.
Press WRITE to insert the code.
C
G
O
HIP
UARD
PTION
The height of the chip guard is adjustable. This may be helpful to gain additional
clearance from the operator pendant. See Haas document ES0607 for height adjustment
instructions.
The linear guide trucks are fi lled with grease at the factory. Under infrequent or light duty
use the factory lube is suffi cient for several months. It is important that the axes are cycled
to their full travel daily to coat the linear guides with grease in order to protect the surfaces.
More severe use, such as cutting absorbent materials (such as wood), or excessive
coolant use (which washes the linear guides), will require weekly greasing - Two strokes
of the supplied grease gun is suffi cient. Do not over grease, as the excessive pressure of
over-greasing or using a pneumatic or an electrical grease gun is harmful to the seals. It is
not necessary to see grease squeezing out of the seals.
Grease type: General-purpose lithium
6
TM-1 pictured. Grease fi tting locations are identical for TM-2 and TM-1P.
Also check the Maintenance chapter of the Operator's manual for additional
maintenance issues.
Note that the Toolroom Mill does not have a gearbox or a TSC system; disregard these
maintenance sections.
12
6 . M AI N T EN AN CE
Y-Axis Linear Guide
Z-Axis Ballnut
X-Axis Linear
Guide
Z-Axis
Linear Guide
X-Axis Ballnut
Y-Axis Ballnut