All new HAAS Toolroom Mills are warranted exclusively by the Haas Automation's
("Manufacturer") limited warranty against defects in material and workmanship for a period
of six (6) months from the date of purchase, which is the date that a machine is installed
at the end user. An additional 6-month extension may be purchased from your authorized
Haas distributor. See the Warranty section of the Mill Operator's Manual for further
warranty information.
Read and Follow all safety warnings
Manual Safety chapter. Be aware of the other people around you in the shop; fl ying chips
can seriously injure people, who may not be a safe distance away. Always wear safety
glasses. Initial cuts/setups should be cut at a slower speed to reduce the possibility of tool
or machine damage. As with any open frame mill, chip screens are highly recommended.
NOTE: These installation recommendations are to be used in
conjunction with those in the Reference Manual. Material
supplied here is given specifi cally for the Toolroom Mill.
E
R
LECTRICITY
EQUIREMENTS
IMPORTANT! REFER TO LOCAL CODE REQUIREMENTS BEFORE WIRING
MACHINES.
• The power source must be grounded
• Frequency range is 47-66 Hz
• Line voltage that does not fl uctuate more than +/-5%
• Voltage imbalance or no more than 2%
• Harmonic distortion is not to exceed 10% of the total RMS voltage
Toolroom Mill
Power Supply
Haas Circuit Breaker
If service run from elec. panel is less than 100' use: 1PH - 8 GA WIRE/3PH - 10 GA WIRE
If service run from elec. panel is more than 100' use: 1PH - 6 GA WIRE/3PH - 8 GA WIRE
WARNING!
A separate earth ground wire of the same conductor size as input power is required to be
connected to the machine chassis. This ground wire is required for operator safety and
proper operation. This ground must be supplied from the main plant ground at the service
entrance, and should be routed in the same conduit as input power to the machine. A local
cold water pipe, or ground rod adjacent to the machine cannot be used for this purpose.
Machine input power must be grounded. The machine will not function properly on
ungrounded power.
The maximum voltage leg-to-leg or leg-to-ground should not exceed 260 volts.
2
1 . WARRAN T Y
2 . SAFET Y
- Familiarize yourself with the Operator's
3 . I N STALLAT I ON
Voltage Requirements
208 3PH / 240V 1PH ±10%
40 AMP
40 AMP
96-0041 Rev T