3. TECHNICAL DATA AND LIMITATIONS OF USE
Supply voltage: 230V, see electrical data plate
Delayed line fuses (230V version): indicative
values (Ampere)
Storage temperature: -10°C +40°C
Electrical
P1 Rated absorbed power [W]
data
P2 [W]
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Hydraulic
Max. flow rate [l/h]
data
Max. head [m]
Max. head [bar]
Max. pressure [bar]
Max suction depth [m/min]
Range of
Length of power cable [m]
use
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [°C]
according to EN 60335-2-41 for
domestic use
Max. particle dimension
Max. ambient temperature [°C]
Weight
DNM GAS
Net/Gross weight approx. [kg]
The pump cannot support the weight of the pipes, which must be supported in some other way.
4. MANAGEMENT
4.1 Storage
All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2 Transport
Avoid subjecting the products to needless impacts and collisions.
4.3 Weight and dimensions
The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.
5. WARNINGS
The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use
the handle provided.
The pump must never be allowed to run when dry
Model
ENGLISH
Model
P1= 650 W
P1= 850 W
P1= 1100 W
P1=650W
P1=850W
650
400
1 ~ 230 AC
3.11
12.5
3.000
39
3.9
8 m / < 3min
H07 RNF
IP X4
0 °C / +35 °C
Clean water
+40 °C
8.64/10.84
9.06/11.26
Table 3
2
Line fuses
230V 50Hz
4
4
6
P1=1.100W
850
1100
600
750
50
3.88
4.58
12.5
16
450
3.180
3.750
43
45
4.3
4.5
6
1.5
F
1'' M
9.84/12.04
Table2