Whale Expanse WW0821U Manual De Instrucciones Para El Usuario página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
Step 1 Find Suitable Location For Water Heater Installation
Consider the following 7 points:
i.
For weight distribution in caravans, the Water Heater must be positioned as close to the axle as possible.
The installer must avoid locating the Water Heater at the very rear and the very front of the vehicle.
ii.
Any surfaces in contact with the Water Heater must be rated to at least 70 degrees C.
iii.
The location must allow access for servicing the Water Heater.
iv.
The flue terminal must be located at the side of the caravan. Acceptable flue lengths are 0.75 metres, 1.25
metres and 2 metres. A flue may be shortened to a minimum length of 0.75m, but must not be cut any
shorter than this. Flues must not be lengthened.
v.
The flue terminal must be positioned at the side of the vehicle, that an awning will never be fitted to.
vi.
Only the Whale flue terminal (supplied with this Water Heater) is permitted to be used in conjunction
with this Water Heater. This flue must not be positioned within 500mm of a refuelling point or fuel
tank breather outlet or any ventilator from the fuel system(s). The flue terminal must not be fitted
within 300mm of a ventilator for the living space or an opening part of a window.
vii.
The flue terminal must only be positioned vertically below an opening part of a window if the appliance is
fitted with an automatic shut-off device to prevent operation when the window is open. The flue terminal
must be a minimum of 300mm below the window.
viii.
If supplied with a reset button the user must be able to access it to clear lockouts.
Step 2 Cut Out Holes for Internal Water Heater
The cut outs in the vehicle floor and bolt hole positions are shown in Fig 20. *These cut outs can be located
anywhere to the front of the Water Heater.
A cut out template is available on request by contacting Webasto.
Screw Holes
Screw Holes
INSTALLATION INSTRUCTIONS - ONBOARD MODELS
Whale Part Number: WW0821O (Suffix: B or R or C)
Fuel refuelling
/ breather vent
Min 500mm
Fig. 19 Installation Locating Diagram
270mm
Fig. 20 Cut Out Hole in Floor
88mm
12
PLEASE NOTE: Step i to viii
for information on Water
Heater and Flue Locations.
KEY
Prohibited area for
Water Heater flue
Screw Holes
*Drain Pipe
20mm Cut Out
In Vehicle Floor
50mm Cut Out
In Vehicle Floor
Fixed Drain Pipe
20mm Cut Out
In Vehicle Floor
* Please Note:
Cut outs can be
located any where to
Screw Holes
the front of the Water
Heater. Please see
Fig. 33.
*Ducting

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Expanse ww0821o

Tabla de contenido