Parameter
Description
Measure type:
0 = pH with two decimal
P1
1 = pH with one decimal
2 = Redox
Level input:
P2
0 = NO
1 = NC
Storage of the ON/OFF
key status at shutdown:
P3
0 = no
1 = yes
Control type:
0 = OFF
1 = ON
2 = ON/OFF acid
P4
3 = Proportional acid
4 = ON/OFF chlorine
5 = Proportional
chlorine
Working threshold
P5
0 to 14.0 (pH)
0 to 999 (mV)
Hysteresis
P6
0 to 2.00 (pH)
0 to 200 (mV)
Delay at start-up
P7
0 to 30 minutes
Alarm delay
P8
0 to 600 minutes
MEANING OF PARAMETERS
P1:
This parameter allows to select the measurement type, pH or redox (mV). When setting P1=0
(pH reading with two decimal), please note that the two decimal places are visble only for
pH values below 10, because the display can show up to three digits. However, generally the
precision of pH measurements with one decimal is sufficient in most applications.