Safety Notes - Dentsply Sirona TPH Spectra ST Instrucciones De Uso

Composite universal
Ocultar thumbs Ver también para TPH Spectra ST:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2

Safety notes

Be aware of the following general safety notes and the special safety
notes in other chapters of these directions for use.
Safety alert symbol.
This is the safety alert symbol. It is used to alert you
to potential personal injury hazards.
Obey all safety messages that follow this symbol to
avoid possible injury.
2.1 Warnings
The material contains methacrylates and polymerizable monomers
which may be irritating to skin, eyes and oral mucosa and may cause
sensitization by skin contact and allergic contact dermatitis in sus-
ceptible persons.
• Avoid eye contact to prevent irritation and possible corneal dam-
age. In case of contact with eyes, rinse with plenty of water and
seek medical attention.
• Avoid skin contact to prevent irritation and possible allergic re-
sponse. In case of contact, reddish rashes may be seen on the
skin. If contact with skin occurs, remove material with cotton and
alcohol and wash thoroughly with soap and water. In case of skin
sensitization or rash, discontinue use and seek medical attention.
K102065-00 TPH Spectra ST_MV01.indd 5
• Avoid contact with oral soft tissues/mucosa to prevent inflam-
mation. If accidental contact occurs, remove material from the tis-
sues. Flush mucosa with plenty of water and expectorate/evacuate
the water. If inflammation of mucosa persists, seek medical attention.
2.2 Precautions
This product is intended to be used only as specifically outlined in
these Instructions for Use.
Any use of this product inconsistent with these Instructions for Use
is at the discretion and sole responsibility of the dental practitioner.
• If refrigerated, allow material to reach room temperature prior to
use.
• Contact with saliva and blood during composite placement may
cause failure of the restoration.
• Use protective measures for the dental team and patients such as
glasses and rubber dam in accordance with local best practice.
• Devices marked "single use" on the labeling are intended for single
use only. Discard after use. Do not reuse in other patients in order
to prevent cross-contamination.
• The syringes and Compules
vent syringes (and Compules
tion) from exposure to spatter or spray of body fluids or contami-
nated hands it is mandatory that the devices are handled offside
the dental unit with clean/disinfected gloves. Discard devices if
contaminated.
• As additional precautionary measure, syringes may be protected
from gross debris but not from all contamination by applying a pro-
tective barrier.
Tips cannot be reprocessed. To pre-
®
Tips when used for indirect applica-
®
29.06.17 14:27
5

Publicidad

Tabla de contenido
loading

Tabla de contenido