 STANDBY: (Orange) This led is lit when the equipment is sensing the AC
voltage at the input. At power-up this led will lit for a second while the systems
checks for the input voltage.
 >250V OVERVOLTAGE PROTECTION: (Red) When activated, the AC
voltage is permanently out of the permitted range of the equipment, so it will
remain under protection until this condition is solved. Revise your connections
and mains power installation and consider that other equipment connected to
this line may have been damaged.
I) AC MAINS INPUT/LINK: Mains supply connection via PowerCon.
 Blue connector for AC in.
 Grey connector to feed other units in parallel. Linking up to 4 units is possible,
provided that a quality cable of a minimum section of 3x2.5mm
Connecting more than 4 units in parallel may lead to a voltage drop in the cable
that will reduce the equipment performance.
Always use mains power cable supplied by manufacturer.
Never connect the Xcellence Line Array cabinets to an unearthed mains
supply or by using an unearthed mains cable.
The X18WE control panel contains the following elements:
A) LCD: Displays basic information about the DSP Status
B) KEYPAD: Allows the user to perform basic operations on the DSP such as IP
address setting, Preset selection, etc.
C) STATUS LEDS: Report a special event happening in the system
 Protect: (Red) A fault condition is being reported by the amplifier. If this LED is
constantly lit even after resetting the device, please contact the technical
service.
 Standby: (Orange) This led is lit when the equipment is set in Low Power
Consumption mode. This mode can only be set through the PC connection.
 Mute: (Orange) The system is muted (amplifiers are disabled). The system
can be muted from the PC remote control or from the keypad.
IMPORTANT: When the amplifier is in MUTE, the PROTECT LED will be also lit to
show that the amplifier is disabled. Also when the system is waking up from the
STANDBY mode, the PROTECT led will be lit for a few seconds. Under these
circumstances the PROTECT LED is reporting that the amplifier is disabled, but not a
fault condition.
D) SIGNAL INPUT LEDS: Monitor the signal arriving at the module input.
 Input: Signal is present at the input. Nominal input level is +8dBu (2Vrms).
 >8 Overload: The input signal exceeds +14dBu (4Vrms), so it will be
compressed. Avoid the continuous lighting of this led in order to preserve the
dynamic range of the audio signal.
E) OUPUT LEDS: Show the amplifier output level
 -24dB: The amplifier is delivering output power at -24dB of its maximum power
 -12dB: The amplifier is delivering output power at -12dB of its maximum power
 Clip: The amplifier is delivering its maximum output power