Remedy Of Faults; Maintenance And Cleaning; Wear Parts - Oase LUNAQUA 3 Instrucciones De Uso

Ocultar thumbs Ver también para LUNAQUA 3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
- GB -
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Switching on: Insert the power plug of the transformer into the socket.
• Check the function of the spotlights.
Switching off: Disconnect the transformer power plug.
Adjusting the light cone
B
Attention! Never loosen the union nut! Water might enter the spotlight.
The light angle can be infinitely adjusted from 10° to 40° by turning the focussing ring (6).

Remedy of faults

Malfunction
Lamp does not light up
Luminosity decreases
Water inside the spotlight housing
S

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
• Ensure that no moisture can enter the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
Replacing the glass or coloured glass and the bulb
C
Undo the screw connections at the mounting plate for nozzle holder, then remove residual water. Ensure that no
moisture can enter the unit. Screw off the union nut, remove the glass or coloured glass and the O ring, check for
damage, replace, if necessary, then remove the bulb from the housing.
Important! Only original bulbs from OASE may be used.
Insert new bulb (do not touch, use a cloth or similar). Reassemble the unit in the reverse order, connect to the power
supply and perform a function check.

Wear parts

Bulbs are wearing parts and are excluded from the warranty.
Repair
Neither the transformer nor the spotlight can be repaired in the event of damage to the cables or the housing and must,
therefore, be replaced.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
8
Cause
Power supply interrupted
Bulb defective
Transformer defective
Lamp glass soiled
The brightness of the bulb reduces as the
operating time increases
Seal defective
Remedy
Check power supply
Replace bulb
Replace transformer
Clean
Replace bulb
Check sealing rings and replace, if necessary

Publicidad