Electric Wiring - Airone TURANDOT ISOLA 60 Instrucciones Para El Uso, Mantenimiento E Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Hoods equipped for remote motors
The hoods equipped for remote motors have a specific connector for the remote motor lead connection. The connect-
or is situated inside the hood. Pass the remote motor lead into the hood through the aperture in the hood itself
(usually near the fume exit hole) and join the two connectors. Refer to the figures in the remote motor instruction
book when performing this operation.
Hoods without motor (Art.*0***) must only be installed and connected with extraction units with a max. output of
640W, as supplied and indicated by the manufacturer.
Once the specialized technician has completed the installation of the hood equipped with a remote motor, all the
leads, connectors, ground connections and the remote motor must not be accessible to the user. Only the installer is
granted access by removing the screwed on panels.
ASSEMBLY INSTRUCTIONS
Attention: Before proceeding with the installation, make sure that the screws and the anchors already sup-
plied, are suitable for the type of wall the hood must be fixed to.
To assemble the hood use the accessories that are supplied and follow the instructions given in the enclosed hand-
book.

ELECTRIC WIRING

The electric wiring must be performed by a specialised electrician fully respecting current standards and legislation
in force. Check that the power supply corresponds to the voltage requested by the hood, which is given on
the silver label stuck inside the hood. Ensure that the wiring system conforms to current standards and the earth
discharge works efficiently. Pay special attention to the hood power cable, ensure that it does not pass through any
holes without a cable clamp. For direct connection to the electrical mains is necessary to provide a device that en-
sures disconnection from the electrical mains, with an opening distance of the contacts that allows the complete
disconnection under the conditions ofovervoltage category III, in accordance with the rules of installation.
The plug or omnipolar switch must be accessible when the unit is installed
If the power cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or
its service agent. The cable used must be of type H05VV-F 3 x 0.75 mm2 minimum cross-section.
The manufacturer declines all responsibility if the current accident prevention standards in force are not
respected, which are needed for the wiring system to operate correctly
CONTROLS
SLIDER CONTROL (Fig. 1)
There are two slider switches on the slider control version.
> One for turning the lights on and off.
> One for turning the motor on and off and for selecting 1^, 2^ or 3^ speed.
KEYBOARD CONTROLS (Fig. 2)
There are four buttons on the keyboard control version:
> One for turning the lights on and off.
> One for turning the motor on at 1st speed and for turning it off.
> One for turning it on at 2nd speed.
> One for turning it on at 3rd speed.
EN - 6